-
Paediatric anaesthesia · Oct 2017
The role of ultrasound in appropriate endotracheal tube size selection in pediatric patients.
- Demet Altun, Mukadder Orhan-Sungur, Achmet Ali, Tülay Özkan-Seyhan, Nükhet Sivrikoz, and Emre Çamcı.
- Department of Anesthesiology, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey.
- Paediatr Anaesth. 2017 Oct 1; 27 (10): 1015-1020.
BackgroundThe aim of this prospective study was to investigate the success of ultrasound in pediatric patients in determining the appropriate sized cuffed endotracheal tube and to compare the results with conventional height-based (Broselow) tape and age-based formula tube size.MethodsOne hundred and fifty-two children of 1-10 years of age, who received general anesthesia for adenotonsillectomy were enrolled to the study. In all participants, the transverse diameter of the subglottis was measured with ultrasound during apnea. An endotracheal tube was chosen with the outer diameter matched to the measured subglottic airway diameter. An age-based (Motoyama-Khine) and height-based (Broselow) endotracheal tube size was calculated. If there was resistance to passage of the tube into the trachea or an airway pressure >25 cmH2 0 was required to detect an audible leak, the endotracheal tube was replaced with internal diameter of 0.5 mm smaller. If there was an audible leak at airway pressure <10 cmH2 O, or peak pressure >25 cmH2 0 or a cuff pressure > 25 cmH2 O was required to seal, the tube was changed to the 0.5 mm larger internal diameter. Best-fit tube internal diameter was the resultant tube internal diameter that met the previously stated conditions. The need for endotracheal tube replacement and peak airway pressure were recorded.ResultsThe internal diameter of ultrasound determined tube was the same as best-fit tube in 88% of children. Endotracheal tube was replaced in 15 patients with a one size larger, and in three patients with one size smaller tube. Using Bland-Altman analysis, a better agreement was observed with ultrasound measurement rather than height-based estimation and age-based formulas.ConclusionOur findings show that subglottic diameter measured by ultrasound appears to be a reliable predictor for the assessment of the subglottic diameter of the airway in estimating appropriate size pediatric endotracheal tube.© 2017 John Wiley & Sons Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.