• Orthop Traumatol Sur · May 2016

    No effect of femoral offset on bone implant micromotion in an experimental model.

    • F Amirouche, G Solitro, and A Walia.
    • University of Illinois at Chicago, Department of Orthopaedics, 835, S. Wolcott avenue, Room E270, Chicago, IL 60612, USA. Electronic address: amirouch@uic.edu.
    • Orthop Traumatol Sur. 2016 May 1; 102 (3): 379-85.

    BackgroundIn total hip replacement (THR), the femoral offset (FO) is assessed preoperatively, and the surgeon must determine whether to restore, increase, or decrease the FO based on experience and the patient's clinical history. The FO is known to influence the abductor muscle strength, range of motion (ROM), gait, and hip pain after THR; however, the true effect of FO on bone implant micromotion is unclear. Therefore, we investigated to assess: (1) the muscle loading response during gait, (2) whether FO affects bone implant micromotion during gait.HypothesisA variation of ±10mm from the anatomical FO affects the muscle loading forces.Materials And MethodsWe modified a personalized musculoskeletal model of the lower extremity to determine the 3-dimensional contact forces at the hip joint in the presence of a stem with varying offsets during a gait cycle. A detailed finite element (FE) model was then constructed for increased, restored, and decreased FOs. The maximum load obtained during normal walking gait from the musculoskeletal model was applied to the respective FE models, and the resultant stem-bone micromotion and stress distribution were computed.ResultsIncreasing the FO to +10mm decreased the peak force generated by the abductor muscles during the cycle by 15.0% and decreasing the FO to -10mm increased the von Mises stress distribution at the distal bone by 77.5% (P<0.05). A variation of the offset within 10mm of the anatomical offset showed no significant differences in micromotion (P>0.05) and peak stresses (P>0.05).DiscussionCoupling the musculoskeletal model of the gait cycle with FE analysis provides a realistic model to understand how FO affects bone implant micromotion. We found that there was no effect of FO on bone implant micromotion; thus, a surgeon does not need to evaluate the implications of FO on micromotion and can determine a FO that best decreases the work load of abductor muscles, increases ROM, and reduces hip pain.Level Of EvidenceIV, biomechanical study.Copyright © 2016 Elsevier Masson SAS. All rights reserved.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.