• Acta Anaesthesiol Scand · Oct 2011

    Positive end-expiratory pressure-induced changes in end-expiratory lung volume measured by spirometry and electric impedance tomography.

    • C Grivans, S Lundin, O Stenqvist, and S Lindgren.
    • Department of Anaesthesiology and Intensive Care, Institute of Clinical Sciences at Sahlgrenska Academy, University of Gothenburg, Sweden. christina.grivans@vgregion.se
    • Acta Anaesthesiol Scand. 2011 Oct 1; 55 (9): 1068-77.

    BackgroundA bedside tool for monitoring changes in end-expiratory lung volume (ΔEELV) would be helpful to set optimal positive end-expiratory pressure (PEEP) in acute lung injury/acute respiratory distress syndrome patients. The hypothesis of this study was that the cumulative difference of the inspiratory and expiratory tidal volumes of the first 10 breaths after a PEEP change accurately reflects the change in lung volume following a PEEP alteration.MethodsChanging PEEP induces lung volume changes, which are reflected in differences between inspiratory and expiratory tidal volumes measured by spirometry. By adding these differences with correction for offset, for the first 10 breaths after PEEP change, cumulative tidal volume difference was calculated to estimate ΔEELV(VT) ((i-e)) . This method was evaluated in a lung model and in patients with acute respiratory failure during a PEEP trial. In patients, ΔEELV(VT) ((i-e)) were compared with simultaneously measured changes in lung impedance, by electric impedance tomography (EIT), using calibration vs. tidal volume to estimate changes in ΔEELV(EIT) .ResultsIn the lung model, there was close correlation (R(2)  = 0.99) between ΔEELV(VT) ((i-e)) and known lung model volume difference, with a bias of -4 ml and limits of agreement of 42 and -50 ml. In 12 patients, ΔEELV(EIT) was closely correlated to ΔEELV(VT) ((i-e)) (R(2)  = 0.92), with mean bias of 50 ml and limits of agreement of 131 and -31 ml. Changes in EELV estimated by EIT (ΔEELV(EIT) ) exceeded measurements by spirometry (ΔEELV(VT) ((i-e)) ), with 15 (±15)%.ConclusionsWe conclude that spirometric measurements of inspiratory-expiratory tidal volumes agree well with impedance changes monitored by EIT and can be used bedside to estimate PEEP-induced changes in EELV.2011 The Authors Acta Anaesthesiologica Scandinavica, 2011 The Acta Anaesthesiologica Scandinavica Foundation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.