• Orthop Traumatol Sur · Dec 2009

    Long-term results of the ABG-1 hydroxyapatite coated total hip arthroplasty: analysis of 111 cases with a minimum follow-up of 10 years.

    • R Bidar, P Kouyoumdjian, E Munini, and G Asencio.
    • Department of Orthopaedics and Traumatology, Carémeau Teaching Hospital Center, place du Pr-Robert-Debré, 30029 Nîmes cedex 9, France. romainbidar@yahoo.fr
    • Orthop Traumatol Sur. 2009 Dec 1; 95 (8): 579-87.

    IntroductionMedium-term studies of ABG-1 cementless total hip arthroplasty have shown favorable functional results with excellent femoral component fixation but an abnormally high rate of periacetabular component osteolysis, which may require early revision.HypothesisThe periacetabular osteolysis rate increases with time with the ABG-1 implant, leading to a high revision rate.ObjectiveThe objective of this study was to test this hypothesis with a minimum follow-up of 10 years and evaluate the progression of periacetabular osteolysis and its consequences on implant fixation.Material And MethodsA continuous series of 111 ABG-1 cementless prostheses implanted by a single operator with a theoretical minimum follow-up of 10 years. Seventy-five implants were analyzed with a mean follow-up of 13 years. All the prostheses had been implanted via a posterolateral approach and consisted of a 28 mm cup matching a head in zirconia and an antidislocation rim design high-density polyethylene insert.ResultsTwelve cups were revised because of progressive retroacetabular osteolysis. The revisions were performed systematically although there was no pain or gross cup loosening. The revisions included resection of the granuloma, cavity filling with morselized bone grafts, and implantation of new uncemented ABG-2 cups in eight cases or cemented cups associated with a support ring in the four other cases. Thirty-two (48.5%) of the cups still in place at the end of the follow-up evaluation presented moderate and asymptomatic radiographic osteolysis, inciting close subsequent observation. No predictive factor of osteolysis onset was identified (age, body mass index, polyethylene wear, or cup orientation). None of the femoral stems was changed because of osteolysis: the only two femoral revisions resulted from periprosthetic fracture and one case of bipolar loosening. The femoral osteolysis images were small and all limited to zones 7a (18.8% of cases), 1a, and 1b (65.2% of cases). The overall survival rate of the series at 13 years of follow-up was 80.5%; the cup survival rate was 83.2%; the femoral implant, 94.3%; and failure of the femoral stem secondary to aseptic loosening was only 1.3%.Discussion, ConclusionThis long-term study confirms the high frequency of retroacetabular osteolysis of ABG-1 prostheses surpassing the osteolysis rate of other uncemented cups with a polyethylene insert. The absence of predictive criteria of osteolysis occurrence and the lack of symptoms warrants periodic follow-up of patients with ABG-1 cups and, if necessary, early repair of bone stock loss with grafts combined with acetabular cup revision. This procedure remains simple as long as performed before the onset of massive bone destruction, confirming the proposed revisions in this series were judicious. This study also confirms the excellent long-term fixation of the ABG-1 femoral stems derived from the osteointegration and proximal seal around the hydroxyapatite coating.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.