J Trauma Acute Care Surg · Apr 2012
Ex vivo evaluation of the polymerization temperatures during cement augmentation of proximal femoral nail antirotation blades.
- Ladina Fliri, Mark Lenz, Andreas Boger, and Markus Windolf.
- Biomedical Services, AO Research Institute, Davos, Switzerland. ladina.fliri@aofoundation.org
- J Trauma Acute Care Surg. 2012 Apr 1; 72 (4): 1098-101.
BackgroundPrevious studies have clearly demonstrated superior biomechanical behavior of augmented proximal femoral nail antirotation (PFNA) blades compared with nonaugmented ones with respect to implant cutout. Nevertheless, there is concern about thermal bone necrosis due to exothermic curing of polymethylmethacrylate (PMMA)-based bone cements. The objective of this study was to quantify the temperatures arising around perforated titanium PFNA blades when augmenting with PMMA.MethodsCylindrical samples from six pairs of fresh frozen human cadaveric femoral heads implanted with a PFNA blade were placed in a 37°C water bath and augmented with 3 mL and 6 mL PMMA. During augmentation, temperatures were measured using six K-type thermocouples that were placed at controlled distances around the implant. With the help of high-resolution quantitative computed tomography images, the locations of all thermocouples with respect to the cement-bone interface were reconstructed.ResultsNo temperatures higher than 45°C were measured in the interface region and the surrounding cement-free cancellous bone. In the same regions, the longest exposure time above 41°C was 8.5 minutes and was measured in a 6-mL sample. Average maximum temperature was significantly lower for the 3-mL group compared with the 6-mL group (p = 0.017).ConclusionThe results of this study suggest that augmentation of titanium PFNA blades is not associated with a risk of thermal bone necrosis when using up to 6 mL of PMMA. However, larger amounts of cement lead to higher temperatures. PMMA application should therefore be kept low to minimally alter the biological system.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.