• Acta Anaesthesiol Scand · Nov 2018

    Clinical Trial Observational Study

    Length-based body weight estimation in paediatric patients: The impact of habitus-A clinical observational trial.

    • A R Schmidt, P K Buehler, J Meyer, M Weiss, A Schmitz, and C P Both.
    • Department of Anaesthesia, University Children's Hospital Zurich, Zurich, Switzerland.
    • Acta Anaesthesiol Scand. 2018 Nov 1; 62 (10): 1389-1395.

    BackgroundPaediatric emergency tapes provide drug dosing based on the patient's estimated body weight. Unfortunately, published data revealed an unsatisfactory accuracy. A newly developed digital algorithm for weight estimation (CLAWAR) allowing a three-staged habitus adaptation (normal, obese, or cachectic; CLAWAR-3) demonstrated a higher accuracy for weight estimation compared to paediatric emergency tapes. However, the incidence of incorrectly evaluated habitus was 27%. A five-staged habitus adaptation with figural images was suggested by Wells et al to improve habitus and weight estimation. Therefore, CLAWAR was modified with five habitus stages including figural images (CLAWAR-5). We hypothized CLAWAR-5 improves the accuracy of weight estimation.MethodsAfter obtaining informed written parental consent patients were included in this single centre, prospective clinical observation trial. Body weight estimations by CLAWAR-3 and CLAWAR-5 within ±10% of the actual body weight were compared. Furthermore, the incidence of correct evaluated habitus was calculated. McNemar Tests were used for statistical analysis. Results presented as median (interquartiles), P < .003 considered significant.ResultsIn total, 312 patients aged 3.3 years (0.7-6.6), with a body length of 95.9 cm (70.0-121.2), weighing 14.8 kg (8.1-22.5), were included. Both CLAWAR-3 and CLAWAR-5 showed equivalent accuracy for weight estimation within the ±10% interval (62.2% vs 60.6%, P = .609). Despite adding figural images, the incidence of correct evaluated habitus with CLAWAR-5 (46.8%) was worse than with CLAWAR-3 (66.7%).ConclusionThe five-staged habitus-adapted method could not improve the accuracy of weight estimation. Furthermore, the error rate of habitus classification was not reduced by the implementation of figural images.© 2018 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…