-
Acta Anaesthesiol Scand · Nov 2018
Clinical Trial Observational StudyLength-based body weight estimation in paediatric patients: The impact of habitus-A clinical observational trial.
- A R Schmidt, P K Buehler, J Meyer, M Weiss, A Schmitz, and C P Both.
- Department of Anaesthesia, University Children's Hospital Zurich, Zurich, Switzerland.
- Acta Anaesthesiol Scand. 2018 Nov 1; 62 (10): 1389-1395.
BackgroundPaediatric emergency tapes provide drug dosing based on the patient's estimated body weight. Unfortunately, published data revealed an unsatisfactory accuracy. A newly developed digital algorithm for weight estimation (CLAWAR) allowing a three-staged habitus adaptation (normal, obese, or cachectic; CLAWAR-3) demonstrated a higher accuracy for weight estimation compared to paediatric emergency tapes. However, the incidence of incorrectly evaluated habitus was 27%. A five-staged habitus adaptation with figural images was suggested by Wells et al to improve habitus and weight estimation. Therefore, CLAWAR was modified with five habitus stages including figural images (CLAWAR-5). We hypothized CLAWAR-5 improves the accuracy of weight estimation.MethodsAfter obtaining informed written parental consent patients were included in this single centre, prospective clinical observation trial. Body weight estimations by CLAWAR-3 and CLAWAR-5 within ±10% of the actual body weight were compared. Furthermore, the incidence of correct evaluated habitus was calculated. McNemar Tests were used for statistical analysis. Results presented as median (interquartiles), P < .003 considered significant.ResultsIn total, 312 patients aged 3.3 years (0.7-6.6), with a body length of 95.9 cm (70.0-121.2), weighing 14.8 kg (8.1-22.5), were included. Both CLAWAR-3 and CLAWAR-5 showed equivalent accuracy for weight estimation within the ±10% interval (62.2% vs 60.6%, P = .609). Despite adding figural images, the incidence of correct evaluated habitus with CLAWAR-5 (46.8%) was worse than with CLAWAR-3 (66.7%).ConclusionThe five-staged habitus-adapted method could not improve the accuracy of weight estimation. Furthermore, the error rate of habitus classification was not reduced by the implementation of figural images.© 2018 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.