Journal of anesthesia · Dec 2018
Randomized Controlled TrialImpact of non-invasive continuous blood pressure monitoring on maternal hypotension during cesarean delivery: a randomized-controlled study.
- Takashi Juri, Koichi Suehiro, Aya Kimura, Akira Mukai, Katsuaki Tanaka, Tokuhiro Yamada, Takashi Mori, and Kiyonobu Nishikawa.
- Department of Anesthesiology, Osaka City University Graduate School of Medicine, 1-5-7 Asahimachi, Abenoku, Osaka, Osaka, 545-8586, Japan.
- J Anesth. 2018 Dec 1; 32 (6): 822-830.
PurposeThis study aimed to investigate the efficacy of the ClearSight™ system (Edwards Lifesciences, Irvine, CA) for reducing the incidence of hypotension compared with the traditional oscillometric blood pressure monitoring in cesarean delivery under spinal anesthesia.MethodsForty patients undergoing cesarean delivery under spinal anesthesia were enrolled. The patients were randomly divided into two groups (Control and ClearSight groups). All patients received spinal anesthesia using 0.5% hyperbaric bupivacaine (11.5 mg) and fentanyl (10 µg). Blood pressure was managed with the same protocol using the ClearSight™ system (ClearSight group) and oscillometric blood pressure monitoring (Control group). Furthermore, we compared the accuracy of the ClearSight™ system with the traditional oscillometric monitoring for blood pressure measurement using Bland-Altman, four-quadrant plot, and polar plot analyses.ResultsThe incidence of hypotension was significantly lower in the ClearSight group from induction to delivery (45% vs. 0%, p < 0.001) and to the end of surgery (50% vs. 20%, p = 0.049). Intraoperative nausea occurred more frequently in the Control group (45% vs. 10%, p = 0.012). The ClearSight™ system demonstrated acceptable accuracy with a bias of - 4.3 ± 11.7 mmHg throughout the procedure. Four-quadrant analysis revealed an excellent trending ability of the ClearSight™ system with a concordance rate of approximately 95%. In the polar plot analysis, the angular bias and concordance rate were - 13.5° ± 19.0° and 76.9%, respectively.ConclusionsThe accuracy and trending ability of the ClearSight™ system for blood pressure measurement was clinically acceptable in cesarean delivery under spinal anesthesia, leading to reductions in maternal hypotension and nausea.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.