-
Minerva anestesiologica · Jul 2019
Discrimination and calibration properties of the hypotension probability indicator during cardiac and vascular surgery.
- Marco Ranucci, Luigi Barile, Federico Ambrogi, Valeria Pistuddi, and Surgical and Clinical Outcome Research (SCORE) Group.
- Department of Cardiothoracic and Vascular Anesthesia and ICU, San Donato IRCCS Policlinic, Milan, Italy - cardioanestesia@virgilio.it.
- Minerva Anestesiol. 2019 Jul 1; 85 (7): 724-730.
BackgroundHypotension during surgery is linked to postoperative complications. Recently, a new hemodynamic algorithm intended to predict hypotensive events (hypotension probability indicator [HPI]) has been developed. The aim of the present study is to test the discrimination and calibration properties of the HPI.MethodsThe intraoperative files of 23 patients undergoing cardiac and major vascular surgery receiving the HPI-based hemodynamic monitoring were retrospectively investigated for prediction of hypotensive events (mean arterial pressure <65 mmHg). The HPI was available at 20 seconds intervals; the values of HPI five to seven minutes before a hypotensive event (HPI5-7) were tested for discrimination and calibration.ResultsThe HPI5-7 has a fair level of discrimination (area under the curve 0.768) and a poor calibration, due to overestimation of the hypotensive risk. At the observed prevalence, a cut-off value of 85% carries a sensitivity of 62.4% and a specificity of 77.7%, a negative predictive value (NPV) of 97.8% and a positive predictive value (PPV) of 12.6%; a value of 98% has a PPV of 64% and an NPV of 95.3%.ConclusionsThe HPI5-7 may offer some useful insights. Values ≤85% carry a clinically acceptable NPV for hypotensive events at the observed prevalence and may represent a "safe zone" during surgery. Values >85% do not carry enough PPV to trigger hemodynamic interventions, but represent a warning signal. Values >98% are highly suggesting a hypotensive event after 5-7 minutes. Further studies exploring the predictive ability of the HPI at different times are needed.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.