    Errors of oscillometric blood pressure measurement as predicted by simulation.

    • Rein Raamat, Jaak Talts, Kersti Jagomägi, and Jana Kivastik.
    • Department of Physiology, University of Tartu, Tartu, Estonia. rein.raamat@ut.ee
    • Blood Press Monit. 2011 Oct 1; 16 (5): 238-45.

    ObjectiveTo study factors affecting the accuracy of oscillometric measurement.MethodsBy means of a computer-based simulator, a variety of arterial pressure pulses of different shapes and amplitudes were composed as an input signal of the model, whereas cuff volume oscillations were obtained as an output signal. The shape of the artery-cuff pressure/volume relationship was modified. Thereafter, oscillation envelopes were drawn and an estimation of systolic and diastolic pressures was performed by implementing fixed characteristic ratios. The mean arterial pressure was estimated using the maximum oscillation criterion. Altogether, 32 combinations of four affecting factors were studied.ResultsFor the studied range of affecting factors, the induced errors in systolic pressure, diastolic pressure, and mean arterial pressures were 15, 14, and 27 mmHg, respectively. Systolic readings moved toward underestimation and diastolic readings moved toward overestimation if pulse pressure increased. Arterial stiffening induced systematic overestimation of the systolic pressure and overestimation or underestimation of the diastolic pressure compared with a normal artery, with errors depending on the interaction of the symmetry and steepness indices of the artery-cuff pressure/volume curve. Errors of mean arterial pressure were proportional to pulse pressure, showing overestimation if stiffness increased and/or arterial pressure pulses became steeper.ConclusionOscillometric readings of systolic and diastolic pressures are strongly influenced by pulse pressure and the shape of the artery-cuff pressure/volume curve, whereas those of the mean arterial pressure are affected by pulse pressure and both the shape of the artery-cuff pressure/volume curve and the shape of the arterial pulse.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.