• Respiratory care · Apr 2019

    Randomized Controlled Trial

    Reproducibility and Validity of the 6-Minute Stationary Walk Test Associated With Virtual Reality in Subjects With COPD.

    • Maria Cm Frade, Ivanize Mm Dos Reis, Renata P Basso-Vanelli, Alexandre F Brandão, and Mauricio Jamami.
    • Spirometry and Respiratory Physiotherapy Laboratory, Universidade Federal de São Carlos, São Carlos, São Paulo, Brazil.
    • Respir Care. 2019 Apr 1; 64 (4): 425433425-433.

    BackgroundThe importance of evaluating the functional capacity of patients with COPD is well known, and there is a wide range of tests described in the literature. The 6-min stationary walk test associated with virtual reality (STVR-6) was created in light of the current limitations of evaluation tests. It does not require a large physical space or sophisticated equipment, and it is not costly; furthermore, it can be performed by a single rater. The objective of this study was to evaluate intra- and inter-rater reproducibility and to verify the criterion validity of the STVR-6.Methods50 subjects with COPD were evaluated over the course of 3 d. The execution order of the tests was randomized; the STVR-6 was performed over 2 d, and the 6-min walk test was performed in 1 d. The 6-min walk distance variables and number of steps in the STVR-6 were obtained with a gas analysis performed for both tests.ResultsRelative reproducibility was found for intraclass correlation coefficient values (0.57-0.94, P < .001) between the number of steps and the highest value of oxygen consumption during the test (V̇O2 peak), intra- and inter-rater. In terms of absolute reproducibility, the standard error of measurement and minimum detectable difference values were verified. In the Bland-Altman analysis, the intra- and inter-rater mean difference values were 21 and 17 steps and 0.002 and 0.242 mL/min/kg, respectively. Pearson correlation values were 0.57-0.75 (P < .001) between the number of steps and V̇O2 peak.ConclusionsSTVR-6 had excellent intra-rater reproducibility and excellent to good inter-rater reproducibility, but the high values of error measures demonstrated that there is a learning effect and a need to perform at least 2 tests. In addition, there was high to moderate correlation between the STVR-6 and the 6-min walk test. Therefore, the STVR-6 proved to be reproducible and valid for evaluating the functional capacity of subjects with COPD.Copyright © 2019 by Daedalus Enterprises.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…