-
Randomized Controlled Trial
Reproducibility and Validity of the 6-Minute Stationary Walk Test Associated With Virtual Reality in Subjects With COPD.
- Maria Cm Frade, Ivanize Mm Dos Reis, Renata P Basso-Vanelli, Alexandre F Brandão, and Mauricio Jamami.
- Spirometry and Respiratory Physiotherapy Laboratory, Universidade Federal de São Carlos, São Carlos, São Paulo, Brazil.
- Respir Care. 2019 Apr 1; 64 (4): 425433425-433.
BackgroundThe importance of evaluating the functional capacity of patients with COPD is well known, and there is a wide range of tests described in the literature. The 6-min stationary walk test associated with virtual reality (STVR-6) was created in light of the current limitations of evaluation tests. It does not require a large physical space or sophisticated equipment, and it is not costly; furthermore, it can be performed by a single rater. The objective of this study was to evaluate intra- and inter-rater reproducibility and to verify the criterion validity of the STVR-6.Methods50 subjects with COPD were evaluated over the course of 3 d. The execution order of the tests was randomized; the STVR-6 was performed over 2 d, and the 6-min walk test was performed in 1 d. The 6-min walk distance variables and number of steps in the STVR-6 were obtained with a gas analysis performed for both tests.ResultsRelative reproducibility was found for intraclass correlation coefficient values (0.57-0.94, P < .001) between the number of steps and the highest value of oxygen consumption during the test (V̇O2 peak), intra- and inter-rater. In terms of absolute reproducibility, the standard error of measurement and minimum detectable difference values were verified. In the Bland-Altman analysis, the intra- and inter-rater mean difference values were 21 and 17 steps and 0.002 and 0.242 mL/min/kg, respectively. Pearson correlation values were 0.57-0.75 (P < .001) between the number of steps and V̇O2 peak.ConclusionsSTVR-6 had excellent intra-rater reproducibility and excellent to good inter-rater reproducibility, but the high values of error measures demonstrated that there is a learning effect and a need to perform at least 2 tests. In addition, there was high to moderate correlation between the STVR-6 and the 6-min walk test. Therefore, the STVR-6 proved to be reproducible and valid for evaluating the functional capacity of subjects with COPD.Copyright © 2019 by Daedalus Enterprises.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.