• Foot Ankle Int · Apr 2016

    Comparative Study

    Biomechanical Comparison of Intramedullary Screw Versus Low-Profile Plate Fixation of a Jones Fracture.

    • Jeannie Huh, Richard R Glisson, Takumi Matsumoto, and Mark E Easley.
    • Department of Orthopaedic Surgery, Dwight D. Eisenhower Army Medical Center, Fort Gordon, GA, USA jhandyh@gmail.com.
    • Foot Ankle Int. 2016 Apr 1; 37 (4): 411-8.

    BackgroundIntramedullary screw fixation of fifth metatarsal Jones fractures often produces satisfactory results, however, nonunion and refracture rates are not negligible. The low-profile "hook" plate is an alternative fixation method that has been promoted to offer improved rotational control at the fracture site, but this remains to be proven. The purpose of this study was to document biomechanical performance differences between this type of plate and a contemporary solid, dual-pitch intramedullary screw in a cadaveric Jones fracture model.MethodsSimulated Jones fractures were created in 8 matched pairs of fresh-frozen cadaveric fifth metatarsals. One bone from each pair was stabilized using an intramedullary TriMed Jones Screw and the other using a TriMed Jones Fracture Plate (TriMed, Inc, Santa Clarita, CA). Controlled bending and torsional loads were applied. Bending stiffness and fracture site angulation, as well as torsional stiffness, peak torque, and fracture site rotation were quantified and compared.ResultsIntramedullary screw fixation demonstrated greater bending stiffness and less fracture site angulation than plate fixation during plantar-to-dorsal and lateral-to-medial bending. Torsional stiffness of screw-fixed metatarsals exceeded that of plate-fixed bones at initial loading; however, as rotation progressed, the plate resisted torque better than the screw. No difference in peak torque was demonstrable between fixation methods, but it was reached earlier in specimens fixed with screws and later in those fixed with plates as rotation progressed.ConclusionIn this cadaveric Jones fracture model, intramedullary screw fixation demonstrated bending stiffness and resistance to early torsional loading that was superior to that offered by plate fixation.Clinical RelevanceAlthough low-profile "hook" plates offer an alternative for fixation of fifth metatarsal Jones fractures, intramedullary screw fixation may provide better resistance to bending and initiation of fracture site rotation. The influence of these mechanical characteristics on fracture healing is unknown, and further clinical investigation is warranted.© The Author(s) 2015.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…