• J Shoulder Elbow Surg · Sep 2001

    The effect of articular malposition after total shoulder arthroplasty on glenohumeral translations, range of motion, and subacromial impingement.

    • G R Williams, K L Wong, M D Pepe, V Tan, D Silverberg, M L Ramsey, A Karduna, and J P Iannotti.
    • Shoulder and Elbow Service, Department of Orthopaedic Surgery, University of Pennsylvania School of Medicine, Philadelphia, USA.
    • J Shoulder Elbow Surg. 2001 Sep 1; 10 (5): 399-409.

    AbstractThe articular surface of the normal humeral head has a variable posterior and medial offset with respect to the central axis of the humeral shaft. Recreation of the normal humeral head shaft offset is postulated to be an important consideration during shoulder arthroplasty. However, the effect of humeral head malposition is unknown. The purpose of this study was to determine the effect of articular malposition after total shoulder arthroplasty on glenohumeral translation, range of motion, and subacromial impingement. Twenty-one human cadavers were dissected and tested with the use of an active or passive shoulder model. Range of motion and translation were recorded by means of an electromagnetic tracking device. The experiment was performed in 2 phases. For kinematics study, 11 cadaver shoulders were positioned both passively and actively from maximum internal rotation to maximum external rotation at 90 degrees of total elevation in the scapular plane. Three rotator cuff and 3 deltoid muscle lines of action were simulated for active joint positioning. Passive joint positioning was accomplished with the use of a torque wrench and a nominal centering force. The testing protocol was used for the natural joint as well as for 9 prosthetic head locations: centered and 2- and 4-mm offsets in the anterior, posterior, inferior, and superior directions. Repeated-measures analysis of variance was used to test for significant differences in the range of motion and translation between active and passive positioning of the natural joint as well as all prosthetic head positions. (2) For impingement study, 10 cadaver shoulders were used in a passive model, loading the tendons of the rotator cuff with a 30-N centering force. The humerus was passively rotated from maximum internal rotation (1500 Nmm) to maximum external rotation (1500 Nmm) by means of a continuous-recording digital torque wrench. Trials were performed with the use of centered, 4-, 6-, and 8-mm offset heads in the anterior, posterior, superior, and inferior positions before and after removal of the acromion and coracoacromial ligament. The relation between change in mean peak torque (with and without acromion), passive range of motion, and humeral head offset was analyzed by means of repeated-measures analysis of variance. In the kinematics study, total range of motion and all humeral translations were greater with passive joint positioning than with active positioning (P =.01) except for total superior-inferior translation and superior-inferior translation in external rotation. Anterior to posterior humeral head offset was associated with statistically significant changes in total range of motion (P =.02), range of internal rotation (P =.02), range of external rotation (P =.0001), and total anterior-posterior translation (P =.01). Superior to inferior humeral head offset resulted in statistically significant changes in total range of motion (P =.02), range of internal rotation (P =.0001), anterior-posterior translation during external rotation (P =.01), and total superior-inferior translation (P =.03). In the impingement study, there was a significant increase in torque from centered to 4-mm inferior offset (P =.006), 6-mm inferior offset (P <.001), and 8-mm inferior offset (P <.001). There was no significant increase in torque with superior, anterior, and posterior offsets. Glenohumeral motion significantly decreased from 129 degrees for centered head to 119 degrees for 8-mm superior (P =.002), 119 degrees for 8-mm anterior (P =.014), 118 degrees for 8-mm inferior (P <.001), and 114 degrees for 8-mm posterior (P =.001). Humeral articular malposition of 4 mm or less during prosthetic arthroplasty of the glenohumeral joint may lead to small alterations in humeral translations and range of motion. Inferior malposition of greater than 4 mm can lead to increased subacromial contact; offset of 8 mm in any direction results in significant decreases in passive range of motion. Therefore if subacromial contact is to be minimized and glenohumeral motion maximized after shoulder replacement, anatomic reconstruction of the humeral head-humeral shaft offset to within 4 mm is desirable.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.