Zhonghua Jie He He Hu Xi Za Zhi · Sep 2016
[The influence of condensate in the piezometric tube on patient ventilator interaction during noninvasive positive pressure ventilation].
- J Y Hu, Z G Zheng, H N Lu, N Liu, W L Wu, Y X Li, Y Xiong, X N Wang, and R C Chen.
- The First Affiliated Hospital of Guangzhou Medical University(State Key Laboratory of Respiratory Diseases), Guangzhou Institute of Respiratory Diseases, Guangzhou 510120, China.
- Zhonghua Jie He He Hu Xi Za Zhi. 2016 Sep 1; 39 (9): 704-8.
ObjectiveTo study the effects of condensate in the piezometric tube on patient ventilator interaction during noninvasive positive pressure ventilation.MethodsEleven healthy adults volunteered to receive noninvasive positive pressure ventilation. Different capacity of physiological saline was injected gradually into the piezometric tube until the volunteers could not trigger the ventilator or the total volume of the water reached 1.5 ml. The dynamic changes of the pressure of mask(Pmask), piezometric tube near mask (Ppro), piezometric tube near breathing machine(Pdis), and the flow were observed.ResultsWith increasing volume of saline injected, the trigger time TItri(Pmask) increased from 0.09(0.07-0.11) to 0.31(0.22-0.39)s, the trigger pressure TPtri(Pmask) increased from 0.26(0.15-0.33) to 2.29(1.76-3.09)cmH2O, and the pressure-time product PTP (Pmask) increased from 0.02(0.01-0.03) to 0.55(0.41-0.68) cmH2O·s. Ineffective triggering rate increased from 0 up to 9 times/min, and spurious triggering rate increased from 0 up to 33 times/min. The plateau pressure of Pmask and Ppro exceeded the preset parameters, increased significantly as compared with 0 ml, from (9.74±0.34)to (15.79±3.10) cmH2O and from(9.80±0.31) to(15.44±3.47) cmH2O. The change of plateau pressure of Pdis was not significant [from (9.85±0.29)to (12.58±2.64)cmH2O]. The baseline pressure of Pmask, Ppro and Pdis changed from (3.67±0.36) to (8.40±3.22) cmH2O, from (3.71±0.32) to (8.13±3.55) cmH2O and from( 3.77±0.32) to (5.36±1.25) cmH2O, respectively. The pressure fluctuation of platform of Pmask increased significantly compare with 0 ml, from 0.60(0.48-0.71) to 7.94(7.11-8.63)cmH2O. The frequency of fluctuation of platform increased as many as 7 times during a single respiratory period. The time when the pressure of the Pdis began to change was delayed to Pmask and Ppro, 0.11(0.08-0.12)s compared with 0 ml.ConclusionCondensate in the piezometric tube during noninvasive positive pressure ventilation could influence patient-ventilator synchrony. To improve patient ventilator interaction in noninvasive positive pressure ventilation, condensate in the piezometric tube should be avoided.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.