-
Critical care medicine · Oct 2019
Comparative StudyAre Peripherally Inserted Central Catheters Suitable for Cardiac Output Assessment With Transpulmonary Thermodilution?
- Sonia D'Arrigo, Claudio Sandroni, Sofia Cacciola, Antonio Maria Dell'Anna, Mauro Pittiruti, Maria Giuseppina Annetta, Cesare Colosimo, and Massimo Antonelli.
- Department of Anesthesiology, Intensive Care and Emergency Medicine, Fondazione Policlinico Universitario "Agostino Gemelli" IRCCS, Rome, Italy.
- Crit. Care Med. 2019 Oct 1; 47 (10): 1356-1361.
ObjectivesPeripherally inserted central catheters are increasingly used in ICU as an alternative to centrally inserted central catheters for IV infusion. However, their reliability for hemodynamic measurements with transpulmonary thermodilution is currently unknown. We investigated the agreement between transpulmonary thermodilution measurements obtained with bolus injection through peripherally inserted central catheter and centrally inserted central catheter (reference standard) using a transpulmonary thermodilution-calibrated Pulse Contour hemodynamic monitoring system (VolumeView/EV1000).DesignProspective method-comparison study.SettingTwenty-bed medical-surgical ICU of a teaching hospital.PatientsTwenty adult ICU patients who required hemodynamic monitoring because of hemodynamic instability and had both peripherally inserted central catheter and centrally inserted central catheter in place.InterventionThe hemodynamic measurements obtained by transpulmonary thermodilution after injection of a cold saline bolus via both centrally inserted central catheter and either a single-lumen 4F or a double-lumen 5F peripherally inserted central catheter using were compared. In order to rule out bias related to manual injection, measurements were repeated using an automated rapid injection system.Measurements And Main ResultsA total of 320 measurements were made. Cardiac index was significantly higher when measured with double-lumen 5F peripherally inserted central catheter than with centrally inserted central catheter (mean, 4.5 vs 3.3 L/min/m; p < 0.0001; bias, 1.24 L/min/m [0.27, 2.22 L/min/m]; bias percentage, 31%). Global end-diastolic index, extravascular lung water index, and stroke volume index were also overestimated (853 ± 240 vs 688 ± 175 mL/m, 12.2 ± 4.2 vs 9.4 ± 2.9 mL/kg, and 49.6 ± 14.9 vs 39.5 ± 9.6 mL/m, respectively; p < 0.0001). Lower, albeit significant differences were found using single-lumen 4F peripherally inserted central catheter (mean cardiac index, 4.2 vs 3.7 L/min/m; p = 0.043; bias, 0.51 L/min/m [-0.53, 1.55 L/min/m]; bias percentage, 12.7%). All differences were confirmed, even after standardization of bolus speed with automated injection.ConclusionsBolus injection through peripherally inserted central catheter for transpulmonary thermodilution using EV1000 led to a significant overestimation of cardiac index, global end-diastolic index, extravascular lung water index, and stroke volume index, especially when double-lumen 5F peripherally inserted central catheter was used (ClinicalTrial.gov NCT03834675).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.