• J. Thorac. Cardiovasc. Surg. · Jul 1996

    Comparative Study

    Measurement of heparin concentration in whole blood with the Hepcon/HMS device does not agree with laboratory determination of plasma heparin concentration using a chromogenic substrate for activated factor X.

    • J F Hardy, S Bélisle, D Robitaille, J Perrault, M Roy, and L Gagnon.
    • Department of Anesthesia, Montreal Heart Institute, Quebec, Canada.
    • J. Thorac. Cardiovasc. Surg. 1996 Jul 1; 112 (1): 154-61.

    UnlabelledMeasurement of circulating heparin concentration has been suggested to optimize anticoagulation during cardiopulmonary bypass. The Hepcon/HMS device (Medtronic HemoTec, Inc., Parker, Colo.) uses heparin/protamine titration to quantitatively determine heparin concentration. Extensive validation of this instrument is still lacking.MethodsAgreement between heparin concentrations measured by the Hepcon/HMS system and by laboratory determination was evaluated in 16 patients undergoing cardiac operations. For laboratory determinations, plasma heparin concentration was derived from the measure of anti-Xa activity by means of chromogenic substrate technique. The Hepcon/HMS instrument and cartridges measured whole blood heparin concentration. Samples were analyzed 5 minutes after administration of heparin, 15 and 30 minutes after the start of cardiopulmonary bypass, 5 minutes after aortic unclamping, at the end of cardiopulmonary bypass, and after administration of protamine. Data were plotted and interpreted according to the method of Bland and Altman: First, a difference less than 1.4 U/ml (i.e., +/- 0.7 U/ml) was chosen as acceptable, because it would not cause major difficulties in clinical interpretation; second, the difference between the two measurement techniques was plotted against the mean of the two measures.ResultsThe mean difference (bias) between heparin concentrations derived by the Hepcon/HMS device and those obtained by laboratory determination was as expected for measures performed on whole blood versus plasma (1.45 U/ml). Nevertheless, heparin concentrations derived by the Hepcon/HMS device may be as much as 2.76 U/ml above or 6.17 U/ml below the concentrations measured in the laboratory, differences well outside the predetermined limits of agreement and clearly unacceptable for clinical purposes.ConclusionWe conclude that heparin concentrations determined with the Hepcon/HMS instrument do not agree with laboratory determination of heparin concentration. Monitoring of heparin concentrations during bypass with the Hepcon/HMS device cannot be recommended.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.