Multicenter Study Comparative Study
Kinetics of manual and automated mechanical chest compressions.
- Riccardo Colombo, Tommaso Fossali, Davide Ottolina, Beatrice Borghi, Paola Bergomi, Elisa Ballone, Roberto Rech, Antonio Castelli, and Emanuele Catena.
- Department of Anesthesia and Intensive Care Unit, ASST Fatebenefratelli Sacco, Luigi Sacco Hospital, Polo Universitario, University of Milan, Milan, Italy. Electronic address: riccardo.colombo@asst-fbf-sacco.it.
- Resuscitation. 2019 Dec 1; 145: 70-74.
AimEarly onset of adequate chest compression is mandatory for cardiopulmonary resuscitation (CPR) following cardiac arrest. Transmission of forces from chest strain to the heart may be variable between manual and mechanical chest compressions. Furthermore, automated mechanical chest devices can deliver an active decompression, thus improving the venous return to the heart. This pilot study investigated the kinetics of cardiac deformation during these two CPR methods.MethodsTransesophageal echocardiographic analysis of the right ventricular wall behind the sternum during CPR was assessed during manual and mechanical chest compression in adult patients admitted to the emergency department for out-of-hospital cardiac arrest.Results9 patients had manual and 11 mechanical chest compression. Mechanical chest compression was characterized by greater right ventricular lateral wall displacement [with a median (IQR) of 3.7 (3.12-4.27) vs. 2.53 (2.27-2.6) cm, p < 0.0001], and lower rising time [123 (102-169) vs. 187 (164-215) ms, p = 0.002], relaxing time [109 (102-127) vs. 211 (133-252) ms, p = 0.0003], compression rate [100.6 (99.6-102.2) vs. 131.9 (125.4-151.4) bpm, p < 0.0001], with compression-decompression time ratio of [1.04 (0.86-1.1) vs. 0.86 (0.78-0.96), p = 0.046].ConclusionMechanical compared to manual chest compression delivered a more rapid compression and decompression of the cardiac structures at an adequate rate, with broader inward-outward movement of the ventricular walls suggesting greater emptying and filling of the ventricles. Transesophageal echocardiography may be a useful tool to assess the adequacy of chest compression without CPR interruption.Copyright © 2019 Elsevier B.V. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.