• Experimental physiology · Oct 2016

    Vascular responsiveness measured by tissue oxygen saturation reperfusion slope is sensitive to different occlusion durations and training status.

    • Kaitlin M McLay, James E Gilbertson, Silvia Pogliaghi, Donald H Paterson, and Juan M Murias.
    • Canadian Centre for Activity and Aging, The University of Western Ontario, London, ON, Canada.
    • Exp. Physiol. 2016 Oct 1; 101 (10): 1309-1318.

    AbstractWhat is the central question of this study? Is the near-infrared spectroscopy-derived measure of tissue oxygen saturation (StO2) reperfusion slope sensitive to a range of ischaemic conditions, and do differences exist between trained and untrained individuals? What is the main finding and its importance? The StO2 reperfusion rate is sensitive to different occlusion durations, and changes in the reperfusion slope in response to a variety of ischaemic challenges can be used to detect differences between two groups. These data indicate that near-infrared spectroscopy-derived measures of StO2, specifically the reperfusion slope following a vascular occlusion, can be used as a sensitive measure of vascular responsiveness. The reperfusion rate of near-infrared spectroscopy-derived measures of tissue oxygen saturation (StO2) represents vascular responsiveness. This study examined whether the reperfusion slope of StO2 is sensitive to different ischaemic conditions (i.e. a dose-response relationship) and whether differences exist between two groups of different fitness levels. Nine healthy trained (T; age 25 ± 3 years; maximal oxygen uptake 63.4 ± 6.7 ml kg-1  min-1 ) and nine healthy untrained men (UT; age 21 ± 1 years; maximal oxygen uptake 46.6 ± 2.5 ml kg-1  min-1 ) performed a series of vascular occlusion tests of different durations (30 s, 1, 2, 3 and 5 min), each separated by 30 min. The StO2 was measured over the tibialis anterior using near-infrared spectroscopy, with the StO2 reperfusion slope calculated as the upslope during 10 s following cuff release. The reperfusion slope was steeper in T compared with UT at all occlusion durations (P < 0.05). For the T group, the reperfusion slopes for 30 s and 1 min occlusions were less than for all longer durations (P < 0.05). The reperfusion slope following 2 min occlusion was similar to that for 3 min (P > 0.05), but both were less steep than for 5 min of occlusion. In UT, the reperfusion slope at 30 s was smaller than for all longer occlusion durations (P < 0.05), and 1 min occlusion resulted in a reperfusion slope that was less steep than following 2 and 3 min (P < 0.05), albeit not different from 5 min (P > 0.05). The present study demonstrated that the reperfusion rate of StO2 is sensitive to different occlusion durations, and that changes in the reperfusion rate in response to a variety of ischaemic challenges can be used to detect differences in vascular responsiveness between trained and untrained groups.© 2016 The Authors. Experimental Physiology © 2016 The Physiological Society.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…