Experimental physiology
-
Experimental physiology · Oct 2016
Vascular responsiveness measured by tissue oxygen saturation reperfusion slope is sensitive to different occlusion durations and training status.
What is the central question of this study? Is the near-infrared spectroscopy-derived measure of tissue oxygen saturation (StO2) reperfusion slope sensitive to a range of ischaemic conditions, and do differences exist between trained and untrained individuals? What is the main finding and its importance? The StO2 reperfusion rate is sensitive to different occlusion durations, and changes in the reperfusion slope in response to a variety of ischaemic challenges can be used to detect differences between two groups. These data indicate that near-infrared spectroscopy-derived measures of StO2, specifically the reperfusion slope following a vascular occlusion, can be used as a sensitive measure of vascular responsiveness. The reperfusion rate of near-infrared spectroscopy-derived measures of tissue oxygen saturation (StO2) represents vascular responsiveness. ⋯ The reperfusion slope following 2 min occlusion was similar to that for 3 min (P > 0.05), but both were less steep than for 5 min of occlusion. In UT, the reperfusion slope at 30 s was smaller than for all longer occlusion durations (P < 0.05), and 1 min occlusion resulted in a reperfusion slope that was less steep than following 2 and 3 min (P < 0.05), albeit not different from 5 min (P > 0.05). The present study demonstrated that the reperfusion rate of StO2 is sensitive to different occlusion durations, and that changes in the reperfusion rate in response to a variety of ischaemic challenges can be used to detect differences in vascular responsiveness between trained and untrained groups.