-
- Nils Rathmann, Michael Kostrzewa, Kerim Kara, Soenke Bartling, Holger Haubenreisser, Stefan O Schoenberg, and Steffen J Diehl.
- 1 Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
- Br J Radiol. 2015 Jan 1; 88 (1055): 20150151.
ObjectiveEvaluation of absolute radiation exposure values for interventional radiologists (IRs) using a multiaxis interventional flat-panel C-arm cone beam CT (CBCT) system with three-dimensional laser guidance for biopsy in a triple-modality, abdominal phantom.MethodsIn the phantom, eight lesions were punctured in two different angles (in- and out-of-plane) using CBCT. One C-arm CT scan was performed to plan the intervention and one for post-procedural evaluation. Thermoluminescent dosemeters (TLDs) were used for dose measurement at the level of the eye lens, umbilicus and ankles on a pole representing the IRs. All measurements were performed without any lead protection. In addition, the dose-area product (DAP) and air kerma at the skin entrance point was documented.ResultsMean radiation values of all TLDs were 190 µSv for CBCT (eye lens: 180 µS, umbilicus: 230 µSv, ankle: 150 µSv) without a significant difference (p > 0.005) between in- and out-of-plane biopsies. In terms of radiation exposure of the phantom, the mean DAP was not statistically significantly different (p > 0.05) for in- and out-of-plane biopsies. Fluoroscopy showed a mean DAP of 7 or 6 μGym(2), respectively. C-arm CT showed a mean DAP of 5150 or 5130 μGym(2), respectively.ConclusionIn our setting, the radiation dose to the IR was distinctly high using CBCT. For dose reduction, it is advisable to pay attention to lead shielding, to increase the distance to the X-ray source and to leave the intervention suite for C-arm CT scans.Advances In KnowledgeThe results indicate that using modern navigation tools and CBCT can be accompanied with a relative high radiation dose for the IRs since detector angulation can make the use of proper lead shielding difficult.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.