-
- Joyce Ky Wu, Emily DeHaas, Richard Nadj, Aloysius Brandon Cheung, Ronald J Dandurand, Zoltán Hantos, Clodagh M Ryan, and Chung-Wai Chow.
- Division of Respirology, Department of Medicine, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada. joyce.wu@uhn.ca.
- Respir Care. 2020 Nov 1; 65 (11): 1687-1693.
BackgroundThe guidelines to conduct and interpret conventional pulmonary function (PFT) tests are frequently reviewed and updated. However, the quality assurance and quality control (QA/QC) guidelines for respiratory oscillometry testing remain limited. QA/QC guidelines are essential for oscillometry to be used as a diagnostic pulmonary function test (PFT) in a clinical setting.MethodsWe developed a QA/QC protocol shortly after oscillometry was introduced in our laboratory as part of a clinical study. The first clinical study began after the research personnel completed 3 h of combined didactic and hands-on training and establishment of a standard operating protocol (SOP) for oscillometry testing. All oscillometry tests were conducted using the initial SOP protocol from October 17, 2017, to April 6, 2018. At this time, the first QA/QC audit took place, followed by revisions to the SOP, the addition of a QA/QC checklist, and the development of a 12-h training program. A second audit of oscillometry tests was conducted from April 9, 2018, to June 30, 2019. Both audits were completed by a registered cardiopulmonary technologist from the Toronto General Pulmonary Function Lab.ResultsThe first audit evaluated 197 paired oscillometry-PFT tests and found 10 tests (5.08%) to be invalid, with a coefficient of variation > 15%. The second audit examined 1,930 paired oscillometry-PFT tests; only 3 tests (0.16%) were unacceptable, with a coefficient of variation > 15%. Improvement in QA/QC was significantly better compared to the first audit (P < .001).ConclusionsAlthough oscillometry requires minimal subject cooperation, application of the principles that govern the conduct and application of a PFT are important for ensuring that oscillometry testing is performed according to acceptability and reproducibility. Specifically, the inclusion of a SOP, a proper training program, a QA/QC checklist, and regular audits with feedback are vital to ensure that oscillometry is conducted accurately and precisely.Copyright © 2020 by Daedalus Enterprises.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.