    • Foot Ankle Int. 2019 Feb 1; 40 (2): 231-236.

    Background:Lesser toe proximal interphalangeal (PIP) joint arthrodesis is one of the most common foot and ankle elective procedures often using K-wires for fixation. K-wire associated complications led to development of intramedullary fixation devices. We hypothesized that X Fuse (Stryker) and Smart Toe (Stryker) would provide stronger and stiffer fixation than K-wire fixation.Methods:12 cadaveric second toe pairs were used. In one group, K-wires stabilized 6 PIP joints, and 6 contralateral PIP joints were fixed with X Fuse. A second group used K-wires to stabilize 6 PIP joints, and 6 contralateral PIP joints were fixed with Smart Toe. Specimens were loaded cyclically with extension bending using 2-N step increases (10 cycles per step). Load to failure and initial stiffness were assessed. Statistical analysis used paired t tests.Results:K-wire average failure force, 91.0 N (SD 28.3), was significantly greater than X Fuse, 63.3 N (SD 12.9) ( P < .01). K-wire average failure force, 102.3 N (SD 17.7), was also significantly greater than Smart Toe, 53.3 N (SD 18.7) ( P < .01). K-wire initial stiffness 21.3 N/mm (SD 5.7) was greater than Smart Toe 14.4 N/mm (SD 9.3) ( P = .02). K-wire failure resulted from bending of K-wire or breaching cortical bone. X Fuse typically failed by implant pullout. Smart Toe failure resulted from breaching cortical bone.Conclusion:K-wires may provide stiffer and stronger constructs in extension bending than the X Fuse or Smart Toe system. This cadaver study assessed stability of the fusion site at time zero after surgery.Clinical Relevance:Our findings provide new data supporting biomechanical stability of K-wires for lesser toe PIP arthrodesis, at least in this clinically relevant mode of cyclic loading.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.