- Chris N Barnes, Donald A Mahler, Jill A Ohar, David A Lombardi, and Glenn D Crater.
- Theravance Biopharma US, Inc., South San Francisco, CA.
- Chest. 2020 Oct 1; 158 (4): 1413-1419.
BackgroundPeak inspiratory flow (PIF) has been proposed as a measure to assess a patient's ability to use dry powder inhalers (DPIs). However, robust quality criteria to determine a repeatability limit for measuring PIF are lacking.Research QuestionsWhat are the repeatability limits for measuring PIF? What is the relationship between PIF measured using the In-Check DIAL device at Diskus (GlaxoSmithKline; PIFD) and HandiHaler (Boehringer Ingelheim; PIFHH) resistances?Study Design And MethodsData from a randomized, controlled, phase 3 trial (study 0149; see Clinical Trial Registration data) were used to define repeatability limits for PIF. In addition, a model to characterize the relationship between PIF measured with the In-Check DIAL device at PIFD and PIFHH was defined using data from two randomized, controlled, phase 3 trials (studies 0128 and 0149).ResultsIn study 0128, the mean values (SD) for PIF at zero resistance and PIFHH were 84.6 (33.4) and 57.3 (26.1) L/min, respectively. In study 0149, the mean values (SD) for PIFD and PIFHH were 42.4 (11.2) and 29.0 (8.3) L/min, respectively. At the mean level, the mean difference between measurement attempts for PIFD and PIFHH was small, < 5 and < 3 L/min, respectively. The repeatability limit was determined as 10 and 5 L/min for PIFD and PIFHH, respectively. Modeling the relationship between PIFD and PIFHH, after controlling for significant covariates, demonstrated that a PIFD value of 60 L/min was approximately equivalent to PIFHH of 40 L/min.InterpretationsThis analysis demonstrated that the two highest values of PIF using the In-Check DIAL device among three inspiratory efforts, met the repeatability limit. Altogether, these data provide guidance for measuring PIF against the simulated resistance of a specific DPI in clinical practice and research studies.Clinical Trial RegistrationClinicalTrials.gov; Nos.: NCT02518139 (study 0128) and NCT03095456 (study 0149); URL: www.clinicaltrials.gov.Copyright © 2020 The Authors. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.