• Chest · Oct 2020

    Peak Inspiratory Flows: Defining Repeatability Limits and a Predictive Equation for Different Inhalers.

    • Chris N Barnes, Donald A Mahler, Jill A Ohar, David A Lombardi, and Glenn D Crater.
    • Theravance Biopharma US, Inc., South San Francisco, CA.
    • Chest. 2020 Oct 1; 158 (4): 1413-1419.

    BackgroundPeak inspiratory flow (PIF) has been proposed as a measure to assess a patient's ability to use dry powder inhalers (DPIs). However, robust quality criteria to determine a repeatability limit for measuring PIF are lacking.Research QuestionsWhat are the repeatability limits for measuring PIF? What is the relationship between PIF measured using the In-Check DIAL device at Diskus (GlaxoSmithKline; PIFD) and HandiHaler (Boehringer Ingelheim; PIFHH) resistances?Study Design And MethodsData from a randomized, controlled, phase 3 trial (study 0149; see Clinical Trial Registration data) were used to define repeatability limits for PIF. In addition, a model to characterize the relationship between PIF measured with the In-Check DIAL device at PIFD and PIFHH was defined using data from two randomized, controlled, phase 3 trials (studies 0128 and 0149).ResultsIn study 0128, the mean values (SD) for PIF at zero resistance and PIFHH were 84.6 (33.4) and 57.3 (26.1) L/min, respectively. In study 0149, the mean values (SD) for PIFD and PIFHH were 42.4 (11.2) and 29.0 (8.3) L/min, respectively. At the mean level, the mean difference between measurement attempts for PIFD and PIFHH was small, < 5 and < 3 L/min, respectively. The repeatability limit was determined as 10 and 5 L/min for PIFD and PIFHH, respectively. Modeling the relationship between PIFD and PIFHH, after controlling for significant covariates, demonstrated that a PIFD value of 60 L/min was approximately equivalent to PIFHH of 40 L/min.InterpretationsThis analysis demonstrated that the two highest values of PIF using the In-Check DIAL device among three inspiratory efforts, met the repeatability limit. Altogether, these data provide guidance for measuring PIF against the simulated resistance of a specific DPI in clinical practice and research studies.Clinical Trial RegistrationClinicalTrials.gov; Nos.: NCT02518139 (study 0128) and NCT03095456 (study 0149); URL: www.clinicaltrials.gov.Copyright © 2020 The Authors. Published by Elsevier Inc. All rights reserved.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.