The American journal of cardiology
-
Despite numerous epidemiologic studies, few data exist on recent trends in admissions to United States hospitals of patients with atrial fibrillation (AF) as a primary diagnosis and on the determinants of outcome of these hospitalizations. In the present study, we investigated recent trends in the incidence of AF admissions to United States hospitals from 1996 to 2001 using a representative sample of all acute-care hospital admissions in the United States provided by the Centers for Disease Control, with special attention to the importance of age, gender, race, and other determinants of outcome, namely, in-hospital mortality.
-
The availability of cardiac ultrasound is limited in developing countries. We evaluated the feasibility and diagnostic capability of a hand-carried cardiac ultrasound device in 126 patients (age 44 +/- 24 years) referred for consultation to a cardiology clinic in rural Mexico. The hand-carried cardiac ultrasound device identified 86 cardiac findings and obviated the need for further comprehensive echocardiographic evaluation in 90% of patients (113 of 126).
-
Limited data have been published on the use of external defibrillators that deliver impedance compensated biphasic (ICB) waveforms in patients. We compared 2 ICB defibrillators, the Heartstream XL (150-150-150 J protocol) and Heartsine Samaritan (100-150-200 J protocol) in 78 consecutive patients in cardiac arrest. ⋯ By the third shock, the Heartsine Samaritan had significantly better performance in removing ventricular fibrillation (p = 0.029). Energy selection for ICB waveforms requires further validation.
-
Comparative Study
Utility and diagnostic accuracy of hand-carried ultrasound for emergency room evaluation of chest pain.
This study examined the utility and accuracy of immediate hand-carried echocardiography in patients presenting to the emergency room with chest pain and a normal or nondiagnostic electrocardiogram. Hand-carried echocardiography was highly concordant (kappa = 0.8) with troponin T tests as well as the discharge diagnosis of acute coronary syndrome, had a 100% sensitivity for the detection of acute coronary syndrome, 93% specificity, and 71% and 100% positive and negative predictive values, respectively.
-
To identify the incidence of pericardial effusion in patients after cardiac surgery using a hand-carried cardiac ultrasound device, 200 patients were assessed on postoperative day 3. If a pericardial effusion was found, patients were monitored for 3 consecutive days with a hand-carried cardiac ultrasound device. ⋯ No difference was found in the incidence of effusion based on the type of cardiac surgery. Of patients with a small pericardial effusion on day 3 after surgery, an additional 2 of 41 (5%) developed cardiac tamponade.