Journal of medical imaging and radiation oncology
-
J Med Imaging Radiat Oncol · Dec 2011
Randomized Controlled Trial Comparative StudyDose comparisons for conformal, IMRT and VMAT prostate plans.
Volumetric-modulated arc therapy (VMAT) is a relatively new treatment technique in radiation therapy. A comparison study of conformal, intensity-modulated radiation therapy (IMRT) and single- and double-arc VMAT plans was undertaken to evaluate the dosimetric impact of this new technology in prostate cases. The research questions were as follows: how does VMAT dosimetry compare with IMRT and conformal plans?; does VMAT increase the volume of bowel receiving lower doses?; are one or two VMAT arcs required for standard prostate cases? ⋯ Single- and double-arc VMAT consistently resulted in favourable or slightly superior dosimetry when compared with static gantry IMRT for prostate cases. Both the VMAT techniques and static gantry IMRT resulted in superior critical tissue sparing when compared with conformal plans.
-
This paper outlines the key results of the Faculty of Radiation Oncology 2010 workforce survey and compares these results with earlier data. ⋯ There are a relatively large and increasing number of radiation oncologists and trainees compared with previous years. The excessive workloads evident in previous surveys appear to have diminished. However, further work is required on assessing the impact of ongoing feminisation and sub-specialisation.