Anesthesia and analgesia
-
Anesthesia and analgesia · Jul 2004
Intrathecal catheterization and solvents interfere with cortical somatosensory evoked potentials used in assessing nociception in awake rats.
We assessed the objective measurement of central sensitization processes in the awake rat after subcutaneous formalin with cortical somatosensory evoked potentials (CSEPs). Cranial extradural electrodes and intrathecal catheters were implanted in adult male Wistar rats. After 7 days of recovery, CSEPs were induced by electrical stimuli at the tail and recorded before/after the injection of 50 microL of 2% formalin into the hindpaw of rats for 1 h. ⋯ We found that the amplitudes of both signals increased (154.3% +/- 10.9% and 168.7% +/- 9.8%, respectively) from 10 min after formalin injection to the end of the 60-min test period. Pretreatment with intrathecal ketorolac dose-dependently prevented the increases induced by formalin in both measured variables. Moreover, the increases in P1-N1 and N2 were markedly attenuated either by intrathecal polyethylene-10 tubing or by the solvents used for injection, thus indicating the need for distinguishing an impaired nociceptive signal from antinociception when the effects of drugs are evaluated.
-
Anesthesia and analgesia · Jul 2004
Case ReportsRecombinant factor VIIa for life-threatening bleeding in high-risk cardiac surgery despite full-dose aprotinin.
We report the case of an orthotopic heart transplant in a patient with multiple previous cardiac surgeries. The case was prolonged and complicated by severe coagulopathy and bleeding despite the use of full-dose aprotinin throughout. ⋯ There was no evidence of unwanted clot formation within the newly transplanted heart or around the intraaortic balloon pump that remained in situ for 72 h postoperatively. With the combined risks of coagulopathy and bleeding as well as acute right ventricular failure with increases in pulmonary vascular resistance, the re-do sternotomy for heart transplant seems to be an ideal situation in which to consider the use of recombinant factor VIIa.
-
Anesthesia and analgesia · Jul 2004
The effects of the delta-opioid agonist SNC80 on hind-limb motor function and neuronal injury after spinal cord ischemia in rats.
Recent investigation suggested neuroprotective efficacy of a delta-opioid agonist in the brain. We investigated the effects of intrathecal treatment with a delta-opioid agonist (SNC80) on spinal cord ischemia (SCI) in rats. SCI was induced with an intraaortic balloon catheter. ⋯ BBB scores in the SNC-9 group were higher compared with those in the V-9 group (P < 0.05), whereas there were no differences in BBB scores between the SNC-11 and V-11 groups. There were significantly more normal neurons in the SNC-9 and SNC-11 groups than in the V-9 and V-11 groups (P < 0.05). The results indicate that intrathecal treatment with the delta-opioid agonist SNC80 can attenuate hind-limb motor dysfunction and neuronal injury after SCI in rats.
-
Anesthesia and analgesia · Jul 2004
Preoperative sciatic nerve block decreases mechanical allodynia more in young rats: is preemptive analgesia developmentally modulated?
Postoperative sensitivity to tactile stimuli differs as a function of age. In this study, we hypothesized that preoperative sciatic nerve block (SNB), by providing preemptive analgesia, would result in better analgesia than postoperative SNB in the young rat. With the paw incision model of postoperative pain, male Sprague-Dawley rats, aged 2 or 4 wk, underwent general anesthesia and then received a left SNB with 5 microL/g of 0.5% bupivacaine or normal saline. ⋯ At 24 h, the threshold was 4.0 +/- 0.7 g in the preoperative SNB group compared with 1.6 +/- 0.3 g in the postoperative SNB group (P = 0.004). There was no difference at any time point between the preoperative and the postoperative SNB in the 4-wk-old animals. These results suggest that preoperative SNB in young animals provides a preemptive analgesic effect on mechanical allodynia that is age or developmentally dependent.