Anesthesia and analgesia
-
Anesthesia and analgesia · Jul 2004
ReviewColonization and bloodstream infection with single- versus multi-lumen central venous catheters: a quantitative systematic review.
There is a controversy as to whether the number of lumens in the central venous catheters may impact the incidence of catheter-related bloodstream infection. We performed a systematic search (MEDLINE, PREMEDLINE, Cochrane Library, EMBASE, BIOSIS Previews, CINAHL, HealthSTAR/Ovid healthstar, bibliographies, any language, to April, 2003) for full reports on randomized comparisons of single-lumen and multi-lumen catheters. Trials had to report on dichotomous data of catheter colonization or bloodstream infection. ⋯ For every 20 single-lumen catheters inserted, one bloodstream infection will be avoided that would have occurred had multi-lumen catheters been used. The risk of catheter colonization is not decreased. Although these conclusions are based on limited data, single-lumen catheters should be used whenever feasible.
-
Anesthesia and analgesia · Jul 2004
ReviewColonization and bloodstream infection with single- versus multi-lumen central venous catheters: a quantitative systematic review.
There is a controversy as to whether the number of lumens in the central venous catheters may impact the incidence of catheter-related bloodstream infection. We performed a systematic search (MEDLINE, PREMEDLINE, Cochrane Library, EMBASE, BIOSIS Previews, CINAHL, HealthSTAR/Ovid healthstar, bibliographies, any language, to April, 2003) for full reports on randomized comparisons of single-lumen and multi-lumen catheters. Trials had to report on dichotomous data of catheter colonization or bloodstream infection. ⋯ For every 20 single-lumen catheters inserted, one bloodstream infection will be avoided that would have occurred had multi-lumen catheters been used. The risk of catheter colonization is not decreased. Although these conclusions are based on limited data, single-lumen catheters should be used whenever feasible.
-
Anesthesia and analgesia · Jul 2004
ReviewBudget negotiation for industry-sponsored clinical trials.
The specialty of anesthesia is well suited to attract industry-sponsored clinical trials and research revenues because of its fundamental contributions to surgery, critical care, and pain medicine. However, the performance and budgeting of industry-sponsored clinical research over the past decade has been significantly altered by the rapid growth of commercially oriented networks of contract-research organizations and site-management organizations. ⋯ Successful budgeting for the performance of an industry-sponsored clinical trial thus requires a thorough understanding of the direct and indirect costs associated with performing clinical research. We reviewed budget and contractual considerations for the successful negotiation and performance of industry-sponsored clinical research.
-
Anesthesia and analgesia · Jul 2004
ReviewVentilation with smaller tidal volumes: a quantitative systematic review of randomized controlled trials.
In this quantitative systematic review we assessed the effects of ventilation with smaller tidal volume (VT) on morbidity and mortality in patients aged 16 yr or older affected by acute lung injury and acute respiratory distress syndrome. Five randomized trials (1202 patients) comparing ventilation using smaller VT and/or low airway driving pressure (plateau pressure 30 cm H2O or less), resulting in VT of 7 mL/kg or less versus ventilation that uses VT in the range of 10 to 15 mL/kg, were identified after a systematic search of The Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, CINAHL, databases of current research, reference lists, and "gray literature." Mortality at day 28 was significantly reduced by lung-protective ventilation (relative risk [RR], 0.74; confidence interval [CI], 0.61-0.88), whereas beneficial effect on long-term mortality was uncertain (RR, 0.84; CI, 0.68-1.05). The comparison between small and conventional VT was not significantly different if a plateau pressure less than or equal to 31 cm H2O in the control group was used (RR, 1.13; CI, 0.88-1.45). Clinical heterogeneity, such as different lengths of follow-up and higher plateau pressures in control arms in two trials, make the interpretation of the combined results difficult.
-
Anesthesia and analgesia · Jul 2004
ReviewVentilation with smaller tidal volumes: a quantitative systematic review of randomized controlled trials.
In this quantitative systematic review we assessed the effects of ventilation with smaller tidal volume (VT) on morbidity and mortality in patients aged 16 yr or older affected by acute lung injury and acute respiratory distress syndrome. Five randomized trials (1202 patients) comparing ventilation using smaller VT and/or low airway driving pressure (plateau pressure 30 cm H2O or less), resulting in VT of 7 mL/kg or less versus ventilation that uses VT in the range of 10 to 15 mL/kg, were identified after a systematic search of The Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, CINAHL, databases of current research, reference lists, and "gray literature." Mortality at day 28 was significantly reduced by lung-protective ventilation (relative risk [RR], 0.74; confidence interval [CI], 0.61-0.88), whereas beneficial effect on long-term mortality was uncertain (RR, 0.84; CI, 0.68-1.05). The comparison between small and conventional VT was not significantly different if a plateau pressure less than or equal to 31 cm H2O in the control group was used (RR, 1.13; CI, 0.88-1.45). Clinical heterogeneity, such as different lengths of follow-up and higher plateau pressures in control arms in two trials, make the interpretation of the combined results difficult.