Journal of analytical toxicology
-
A selected ion monitoring gas chromatographic/mass spectrometric method for the quantitative determination of benzene in air, breath, and blood was developed utilizing a headspace assay with benzene-d3 as an internal standard. Limits of detection for 2 ng/mL in blood and 0.1 ppb in a 5-L sample of air or breath were attained. ⋯ For cases where background contamination could not be adequately controlled, the assay was modified for the quantitative determination of labelled benzenes six mass units heavier than natural benzene (benzene-d6 or benzene-13C6). Use of the method for the analysis of natural benzene was illustrated for the measurement of background levels in urban smokers and nonsmokers.