The objective of this study was to compare three different hemoconcentrators (Hemocor HPH 400, Mini, and Junior) with two different neonatal ECMO circuits using a roller or a centrifugal pump at different pseudo-patient pressures and flow rates in terms of hemodynamic properties. This evidence-based research is necessary to optimize the ECMO circuitry for neonates. The circuits used a 300-mL soft-shell reservoir as a pseudo-patient approximating the blood volume of a 3 kg neonate, two blood pumps, and a Quadrox-iD Pediatric oxygenator with three different in-line hemoconcentrators (Hemocor HPH 400, Mini, and Junior). ⋯ While the THE delivered to the patient indicates similar perfusion for these patients with any of the three hemoconcentrators, the differences in added resistance to the circuit may impact the decision of which hemoconcentrator is used. There was no clinically significant difference between the two circuits with the roller versus centrifugal pump in terms of hemodynamic properties in this study. Further in vivo research is warranted to confirm our findings.
-
In this work, the study results of an implantable pediatric rotary blood pump (PRBP) are presented. They show the results of the numerical simulation of fluid flow rates in the pump. The determination method of the backflows and stagnation regions is represented. ⋯ The left ventricle becomes fully supported at a pump speed of 10 000 rpm. At a pump speed of 14 000 rpm, the left ventricle goes into a suction state in which fluid almost does not accumulate in the ventricle and only passes through it to the pump. The proposed PRBP showed potential for improved clinical outcomes in pediatric patients with a body surface area greater than 0.6 m2 and weight greater than 12 kg.
-
The purpose of this study was to compare the Capiox FX15 oxygenator with integrated arterial filter to the Capiox RX15 oxygenator with separate Capiox AF125 arterial filter in terms of hemodynamic properties and gaseous microemboli (GME) capturing. Trials were conducted at varying flow rates (2.0 L/min, 3.0 L/min, 4.0 L/min), temperatures (30°C, 35°C), and flow modalities (pulsatile, nonpulsatile). Pressure and flow waveforms were recorded using a custom-made data acquisition system. ⋯ There was a slight generation of surplus hemodynamic energy (SHE) at the pre-oxygenator site for both oxygenators under "nonpulsatile mode." However, higher pre-oxygenator SHE levels were recorded for both groups with "pulsatile mode." The RX15 and FX15 groups were both able to remove all microemboli from the circuit at 2 L/min and 3 L/min in "nonpulsatile mode." Microemboli were delivered to the patient at 4 L/min with pulsatile flows in both groups. The RX15 oxygenator with separate AF125 arterial filter and FX15 oxygenator with integrated arterial filter performed similarly in terms of hemodynamic performance and microemboli capturing. Pulsatile flows at 4 L/min produced instantaneous flow rates that surpassed the documented maximum flow rates of the oxygenators and might have contributed to the delivery of GME to the pseudo-patient.
-
The objective of this study was to evaluate the hemodynamic performance and gaseous microemboli (GME) handling ability of a simulated neonatal extracorporeal life support (ECLS) circuit with an in-line continuous renal replacement therapy (CRRT) device. The circuit consisted of a Maquet RotaFlow centrifugal pump or HL20 roller pump, Quadrox-iD Pediatric diffusion membrane oxygenator, 8-Fr arterial cannula, 10-Fr venous cannula, and Better-Bladder (BB) with "Y" connector. A second Quadrox-I Adult oxygenator was added postarterial cannula for GME experiments. ⋯ At 600 mL/min C lost more THE (81.4%) (P < 0.01) with a larger pressure drop across the oxygenator (95.6 mm Hg) (P < 0.01) than without CRRT (78.3%; 49.1 mm Hg) (P < 0.01). C also demonstrated a poorer GME handling ability using the roller pump, with 87.1% volume and 17.8% count reduction across the circuit, compared to A and B with 99.9% volume and 65.8-72.3% count reduction. These findings suggest that, in contrast to A and B, adding CRRT at position C is unsafe and not advised for clinical use.
-
Extracorporeal life support (ECLS) weaning is a complex interdisciplinary process with no clear guidelines. To assess ventricular and pulmonary function as well as hemodynamics including end-organ recovery during ECLS weaning, we developed a standardized weaning protocol. We reviewed our experience 2 years later to assess its feasibility and efficacy. ⋯ Our generally successful protocol-guided weaning rate (with at least 24-h survival) was 89%, with a discharge home rate of 58%. Practical application of the novel standard protocol seems to facilitate ECLS weaning and to improve its success rate. The protocol can be administered as part of standard bedside ICU assessment.