A technique to prevent dural adhesions to chronically implanted microelectrode arrays.
Minimizing relative movements between neural tissues and arrays of microelectrodes chronically implanted into them is expected to greatly enhance the capacity of the microelectrodes to record from single cortical neurons on a long-term basis. We describe a new surgical technique to minimize the formation of adhesions between the dura and an implanted electrode array using a 12 microm (0.5 mil) thick sheet of Teflon film positioned between the array and the dura. A total of 15 cats were implanted using this technique. ⋯ No significant change was found in the density of cell bodies around implanted electrodes of four of the implanted electrode arrays. However, histological evaluation of the implant sites revealed evidence of meningeal proliferation beneath the arrays. The technique described is shown to be effective at preventing adhesions between implanted electrode arrays and improve the characteristics of chronic recordings obtained with these structures.
-
J. Neurosci. Methods · Apr 2000
Assessing spatial vision - automated measurement of the contrast-sensitivity function in the hooded rat.
The contrast-sensitivity function (CSF) provides a concise and thorough description of an organism's spatial vision; it is widely used to describe vision in animals and humans, to track developmental changes in vision, and to compare vision among different species. Despite the predominance of rats in neuroscience research, their vision is not thoroughly studied due to the complexity of psychophysical measurement and a generally held notion that rat vision is poor. We therefore designed an economical and rapid method to assess the hooded rat's CSF, using a computer monitor to display stimuli and an infrared touch screen to record responses. ⋯ Psychometric functions were obtained by maximum-likelihood fitting of a logistic function to the raw data, obtaining the threshold as the function's point of inflection. As in previous studies with rats, CSFs showed an inverse-U shape with peak sensitivity at 0.12 cyc/deg and acuity just under 1 cyc/deg. The results indicate the present computer-controlled behavioral testing device is a precise and efficient instrument to assess spatial visual function in rats.
-
J. Neurosci. Methods · Apr 2000
Clinical TrialChronaxie calculated from current-duration and voltage-duration data.
To determine the rheobase and the chronaxie of excitable cells from strength-duration curves both constant-current pulses and constant-voltage pulses are applied. Since the complex impedance of the electrode-tissue interface varies with both the pulsewidth and the stimulation voltage, chronaxie values estimated from voltage-duration measurements will differ from the proper values as determined from current-duration measurements. To allow a comparison of chronaxie values obtained by the two stimulation methods, voltage-duration curves were measured in human subjects with a deep brain stimulation electrode implanted, while the current and the load impedance of the stimulation circuit were determined in vitro as a function of both stimulation voltage and pulsewidth. ⋯ It was also shown that in the normal range of stimulation amplitudes (up to 7 V) the load impedance increases almost linearly with the pulsewidth. This result led us to present a simple method to convert voltage-duration data into current-duration data, thereby reducing the error in the calculated chronaxie values to approximately 6%. For this purpose voltage-duration data have to be measured for pulses up to 10-20 times the expected chronaxie.