Development and validation of a computed tomography-based methodology to measure carpal kinematics.
Motion of the wrist bones is complicated and difficult to measure. Noninvasive measurement of carpal kinematics using medical images has become popular This technique is difficult and most investigators employ custom software. The objective of this paper is to describe a validated methodology for measuring carpal kinematics from computed tomography (CT) scans using commercial software. ⋯ The mean error in distal radius surface matching was 2.4 mm and 1.2 deg compared to the use of a registration block. Carpal kinematics measured using the described methodology were accurate, reproducible, and similar to findings of previous investigators. The use of commercially available software should broaden the access of researchers interested in measuring carpal kinematics using medical imaging.