Journal of biomechanical engineering
-
Development of an optimal systemic drug delivery strategy to the brain will require noninvasive or minimally invasive methods to quantify the permeability of the cerebral microvessel wall or blood-brain barrier (BBB) to various therapeutic agents and to measure their transport in the brain tissue. To address this problem, we used laser-scanning multiphoton microscopy to determine BBB permeability to solutes (P) and effective solute diffusion coefficients (Deff) in rat brain tissue 100-250 μm below the pia mater. The cerebral microcirculation was observed through a section of frontoparietal bone thinned with a microgrinder. ⋯ The corresponding mean ratio of Deff to the free diffusion coefficient Dfree, Deff/Dfree, were 0.46, 0.19, 0.12, 0.12, 0.11, and 0.11 for these solutes. While there is a significant difference in Deff/Dfree between small (e.g., sodium fluorescein) and larger solutes, there is no significant difference in Deff/Dfree between solutes with molecular weights from 20,000 to 160,000 Da, suggesting that the relative resistance of the brain tissue to macromolecular solutes is similar over a wide size range. The quantitative transport parameters measured from this study can be used to develop better strategies for brain drug delivery.
-
Comparative Study
Comparison among different high porosity stent configurations: hemodynamic effects of treatment in a large cerebral aneurysm.
Whether treated surgically or with endovascular techniques, large and giant cerebral aneurysms are particularly difficult to treat. Nevertheless, high porosity stents can be used to accomplish stent-assisted coiling and even standalone stent-based treatments that have been shown to improve the occlusion of such aneurysms. Further, stent assisted coiling can reduce the incidence of complications that sometimes result from embolic coiling (e.g., neck remnants and thromboembolism). ⋯ A computational simulation of the full-Y configuration aligned well with the experimental and in vivo findings, indicating potential for clinically useful prediction of post-treatment hemodynamics. This study found that applying different stent configurations resulted in considerably different fluid dynamics in an anatomically accurate aneurysm model and that the full-Y configuration performed best. The study indicates that knowledge of how stent configurations will affect post-treatment hemodynamics could be important in interventional planning and demonstrates the capability for such planning based on novel computational tools.
-
Currently, the diagnosis of coronary stenosis is primarily based on the well-established functional diagnostic parameter, fractional flow reserve (FFR: ratio of pressures distal and proximal to a stenosis). The threshold of FFR has a "gray" zone of 0.75-0.80, below which further clinical intervention is recommended. An alternate diagnostic parameter, pressure drop coefficient (CDP: ratio of trans-stenotic pressure drop to the proximal dynamic pressure), developed based on fundamental fluid dynamics principles, has been suggested by our group. ⋯ This artificial increase in the FFR value within or above the "gray" zone for an upstream intermediate stenosis when in series with a clinically relevant downstream stenosis could lead to misinterpretation of functional stenosis severity. In contrast, a distinct range of CDP values was observed for each case of upstream stenosis (mild: 8-10; intermediate: 47-54; and severe: 130-155). The nonoverlapping range of CDP could better delineate the effect of the downstream stenosis from the upstream stenosis and allow for the accurate diagnosis of the functional severity of the upstream stenosis.
-
Availability of accurate three-dimensional (3D) kinematics of lumbar vertebrae is necessary to understand normal and pathological biomechanics of the lumbar spine. Due to the technical challenges of imaging the lumbar spine motion in vivo, it has been difficult to obtain comprehensive, 3D lumbar kinematics during dynamic functional tasks. The present study demonstrates a recently developed technique to acquire true 3D lumbar vertebral kinematics, in vivo, during a functional load-lifting task. ⋯ Maximum out-of-plane rotations (<1.91 deg) and translations (<0.94 mm) were small compared to the dominant motion in the sagittal plane. The demonstrated success in capturing continuous 3D in vivo lumbar intervertebral kinematics during functional tasks affords the possibility to create a baseline data set for evaluating the lumbar spinal function. The technique can be used to address the gaps in knowledge of lumbar kinematics, to improve the accuracy of the kinematic input into biomechanical models, and to support development of new disk replacement designs more closely replicating the natural lumbar biomechanics.
-
This study is aimed to develop a high quality, extensively validated finite element (FE) human head model for enhanced head injury prediction and prevention. The geometry of the model was based on computed tomography (CT) and magnetic resonance imaging scans of an adult male who has the average height and weight of an American. A feature-based multiblock technique was adopted to develop hexahedral brain meshes including the cerebrum, cerebellum, brainstem, corpus callosum, ventricles, and thalamus. ⋯ A maximum principal strain of 0.42% was adopted for skull cortical layer fracture and maximum principal stress of 20 MPa was used for skull diploë layer fracture. Additionally, a plastic strain threshold of 1.2% was used for facial bone fracture. For brain contusion, 277 kPa of brain pressure was calculated from reconstruction of one contusion case.