Comparative StudyA comparison of temperature-taking methods in neonates.
The purpose of this study was to compare temperature measurements from glass/mercury thermometers to Tempa.Dot Single-Use Clinical Thermometer, B-D Digital Fever Thermometer, Mon-a-Therm Model 1000 Skin Temperature Monitor, IVAC CORE.CHECK Tympanic Thermometer, and IncuTemp3 radiant warmer skin temperature sensor measurements. The effects of ten environmental, developmental, and pharmacological factors on thermometer readings were also assessed. ⋯ The B-D Digital Fever thermometer had the highest correlation with the glass/mercury thermometer for axillary temperature. Tempa.DOT measurements showed the next highest correlation with the glass/mercury thermometer measurements. Tympanic temperature measured by CORE.CHECK was moderately correlated with the glass/mercury thermometer measurement. Skin temperatures were influenced by nesting, clothing, swaddling, and probe site placement. Tympanic readings showed effects of bed type and environmental temperature.