Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine
-
SNR-optimized phase-sensitive dual-acquisition turbo spin echo imaging: a fast alternative to FLAIR.
Phase-sensitive dual-acquisition single-slab three-dimensional turbo spin echo imaging was recently introduced, producing high-resolution isotropic cerebrospinal fluid attenuated brain images without long inversion recovery preparation. Despite the advantages, the weighted-averaging-based technique suffers from noise amplification resulting from different levels of cerebrospinal fluid signal modulations over the two acquisitions. The purpose of this work is to develop a signal-to-noise ratio-optimized version of the phase-sensitive dual-acquisition single-slab three-dimensional turbo spin echo. ⋯ Numerical simulations of the Bloch equations were performed to evaluate signal evolutions of brain tissues along the echo train and optimize imaging parameters. In vivo studies demonstrate that compared with conventional phase-sensitive dual-acquisition single-slab three-dimensional turbo spin echo, the proposed optimization yields 74% increase in apparent signal-to-noise ratio for gray matter and 32% decrease in imaging time. The proposed method can be a potential alternative to conventional fluid-attenuated imaging.
-
Center-out echo-planar spectroscopic imaging with correction of gradient-echo phase and time shifts.
A procedure to prevent the formation of image and spectral Nyquist ghosts in echo-planar spectroscopic imaging is introduced. It is based on a novel Cartesian center-out echo-planar spectroscopic imaging trajectory, referred to as EPSICO, and combined with a correction of the gradient-echo phase and time shifts. ⋯ The proposed center-out trajectory passively prevents the formation of Nyquist ghosts by privileging the acquisition of the center k-space line with forward echoes at the beginning of an echo-planar spectroscopic imaging dwell time and by ensuring that all k-space lines and their respective complex conjugates are acquired at equal time intervals. With the proposed procedure, concentrations of N-acetyl aspartate, creatine, choline, glutamate, and myo-inositol were reliably determined in human white matter at 3 T.
-
Off-resonance radiofrequency saturation pulses applied prior to regular excitation in MR sequences can be used to modify signal contrast based on magnetization transfer and direct saturation effects. Clinical applicability and value of ultrashort echo time sequences combined with off-resonance saturation pulses was tested in 16 healthy and 14 tendinopathic as well as paratendinopathic Achilles tendons in vivo at 3 T. ⋯ Off-resonance saturation ratio in tendons of healthy volunteers ranged from 0.52 ± 0.06 (1000 Hz) to 0.24 ± 0.02 (5000 Hz), whereas symptomatic tendinopathic tendons (0.35 ± 0.04 to 0.17 ± 0.02) and asymptomatic tendinopathic tendons (0.41 ± 0.06 to 0.21 ± 0.02) showed significantly lower mean off-resonance saturation ratio values. Off-resonance saturation ratio values might provide a sensitive and quantitative marker for assessment of pathological microstructure alterations of the Achilles tendon.