CEST is commonly used to probe the effects of chemical exchange. Although R1ρ asymmetry quantification has also been described as a promising option for detecting the effects of chemical exchanges, the existing acquisition approaches are highly susceptible to B1 RF and B0 field inhomogeneities. To address this problem, we report a new R1ρ asymmetry imaging approach, AC-iTIP, which is based on the previously reported techniques of irradiation with toggling inversion preparation (iTIP) and adiabatic continuous wave constant amplitude spin-lock RF pulses (ACCSL). We also derived the optimal spin-lock RF pulse B1 amplitude that yielded the greatest R1ρ asymmetry. ⋯ The AC-iTIP approach could probe the chemical exchange effect more robustly than the existing R1ρ asymmetry acquisition approaches. Therefore, AC-iTIP is a promising technique for metabolite imaging based on the chemical exchange effect.
-
We introduce and validate a scalable retrospective motion correction technique for brain imaging that incorporates a machine learning component into a model-based motion minimization. ⋯ The separability and convergence improvements afforded by the combined convolutional neural network+model-based method shows the potential for meaningful postacquisition motion mitigation in clinical MRI.
-
To develop a free-running (free-breathing, retrospective cardiac gating) 3D myocardial T1 mapping with isotropic spatial resolution. ⋯ The proposed free-running whole heart T1 mapping method allows for reconstruction of isotropic resolution 3D T1 maps at different cardiac phases, serving as a promising tool for whole heart myocardial tissue characterization.
-
To compare gradient echo (GRE) and gradient echo sampling of spin echo (GESSE) sequences for the quantification of the oxygen extraction fraction (OEF) from combined quantitative BOLD and quantitative susceptibility mapping (QSM) with regard to accuracy, precision and parameter initialization. ⋯ GESSE yields higher parameter accuracy in simulated gray matter but produces unphysiological gray-white matter contrast in OEF in vivo. GRE produces uniform OEF maps in vivo and is more efficient, which could facilitate a clinical implementation, but revealed biases in simulation. The appropriate sequence should be chosen depending on application.
-
Motion is 1 extrinsic source for imaging artifacts in MRI that can strongly deteriorate image quality and, thus, impair diagnostic accuracy. In addition to involuntary physiological motion such as respiration and cardiac motion, intended and accidental patient movements can occur. Any impairment by motion artifacts can reduce the reliability and precision of the diagnosis and a motion-free reacquisition can become time- and cost-intensive. Numerous motion correction strategies have been proposed to reduce or prevent motion artifacts. These methods have in common that they need to be applied during the actual measurement procedure with a-priori knowledge about the expected motion type and appearance. For retrospective motion correction and without the existence of any a-priori knowledge, this problem is still challenging. ⋯ Deep learning-based retrospective restoration of motion artifacts is feasible resulting in near-realistic motion-free images. However, the image translation task can alter or hide anatomical features and, therefore, the clinical applicability of this technique has to be evaluated in future studies.