Prospective randomized study for an injection protocol for intravenous contrast media in abdominal and pelvic helical CT.
To develop an injection protocol for intravenous administration of contrast media in abdominal and pelvic helical CT which provides optimal contrast enhancement of arterial and venous vessels. ⋯ For routine abdominal and pelvic helical CT, we recommend an injection of 120 ml contrast medium with a flow rate of 3.0 ml/s. Contrast-enhanced examination of the liver should be started after 50 s, and examination of the lower abdomen and pelvis region should be performed without any further delay. This gives an appropriate contrast in the major vessels.