Acta radiologica
-
Background Cardiac and liver iron assessment using magnetic resonance imaging (MRI) is non-invasive and used as a preclinical "endpoint" in asymptomatic patients and for serial iron measurements in iron-overloaded patients. Purpose To compare iron measurements between hepatic and myocardial T2* and T2 at 1.5T and 3T MRI in normal and iron-overloaded patients. Material and Methods The T2 and T2* values from the regions of interest (ROIs) at mid-left ventricle and mid-hepatic slices were evaluated by 1.5T and 3T MRI scans for healthy and iron-overloaded patients. ⋯ Conclusion Our study found myocardial T2 (1.5T) nearly equal to T2 (3T) with myocardial T2* (3T) 1.75 shorter than myocardial T2* (1.5T). The relationship of hepatic T2* (1.5T) and hepatic T2* (3T) was linear with T2* (1.5T) approximately double to T2* (3T) in iron-overloaded patients. This linear relationship between hepatic T2* (1.5T) and hepatic T2 (3T) could be an alternative method for estimating liver iron concentration (LIC) from 3T.