Acta radiologica
-
Observational Study
UTE T2* mapping of tendinopathic patellar tendons: an MRI reproducibility study.
There is currently a lack of imaging modalities that can be used as a sensitive measure in tendinopathy. Recent findings suggest the applicability of ultra-short echo time (UTE) magnetic resonance imaging (MRI) T2* mapping in tendons, but the reproducibility remains unknown. ⋯ These data demonstrate a small bias between repeated measurements for UTE T2*, but with a very low associated mean difference (3.7%) between the two tests. The high ICC values and low typical error % demonstrate reproducibility of repeated T2*-mapping sessions. Further, the method showed substantial intra- and inter-observer reproducibility for T2* values proving feasibility for use of UTE T2* mapping in research and clinical practice.