Journal of clinical anesthesia
- 
    Randomized Controlled Trial Comparative Study
Fospropofol disodium versus propofol for long-term sedation during invasive mechanical ventilation: A pilot randomized clinical trial.
Fospropofol disodium is a propofol prodrug that is water-soluble and has a reduced risk of bacterial contamination and hypertriglyceridemia compared with propofol. Prior to implementing a large randomized trial, we investigated the feasibility, initial efficacy, and safety of fospropofol disodium compared with propofol in long-term mild-to-moderate sedation in intensive care units (ICUs). ⋯ Fospropofol disodium appears to be a feasible, effective and safe sedative for patients receiving invasive mechanical ventilation with long-term sedation.
 - 
    Randomized Controlled Trial
Comparative evaluation of nebulized versus intravenous dexmedetomidine on intubating conditions during awake fiberoptic nasotracheal intubation.
There is a search for an ideal agent to facilitate awake fiberoptic intubation (AFOI). Dexmedetomidine is a selective α2 agonist which can be administered through intravenous, intramuscular, buccal, intranasal & inhalational routes. It provides good intubation conditions without oxygen desaturation but may cause hypotension and bradycardia when administered intravenously. Hence, alternative routes of administering dexmedetomidine which may improve its safety profile are worth exploring. ⋯ Nebulisation with dexmedetomidine results in desirable degree of sedation and better tolerance of the procedure with adequate attenuation of the haemodynamic responses to intubation.
 - 
    
    
Dementia is a prevalent neurological condition, yet the relationship between dementia and general anesthesia remains uncertain. The study aimed to explore the association between general anesthesia and dementia using a nationwide population-based database. ⋯ Neither general anesthesia nor regional anesthesia in hip/knee surgery was associated with dementia. Different numbers and durations of anesthesia exposure showed no significant differences in the odds for dementia.
 - 
    
Nasal cannula and face mask gas flow rates when connecting to the Y-piece of the anesthesia circuit.
To determine the relationship between the delivered gas flows via nasal cannulas and face masks and the set gas flow and the breathing circuit pressure when connecting to the Y-adapter of the anesthesia breathing circuit and using the oxygen blender on the anesthesia machine, relevant to surgery when there is concern for causing a fire. The flow rates that are delivered at various flow rates and circuit pressures have not been previously studied. ⋯ When using a nasal cannula adapted to the Y-piece of the anesthesia circuit, the delivery system is linearly dependent on the pressure in the circuit and uninfluenced by the flow rate set on the anesthesia machine. However, only modest flow rates (≤ 3.5 L/min) and a limited increase in the inspired FiO2 are possible when using this delivery method. When using a face mask and the anesthesia circuit, flow rates close to the set flow rate are possible with the APL valve fully closed. Patients scheduled for sedation for head and neck procedures with increased fire risk who require more than a marginal increase in the FiO2 to maintain an acceptable pulse oximetry saturation may need general anesthesia with tracheal intubation.