Pediatric radiology
-
Coins are the most commonly encountered foreign body ingestions presenting to the emergency department (ED). The purpose of our study was to retrospectively evaluate a new institutional protocol implemented in 1998, in which healthy patients with acute (less than 24 h) coin ingestions located below the thoracic inlet, were observed at home with next-day follow-up. If repeat radiographs revealed a persistent esophageal foreign body, then the coin was removed. ⋯ Patients with acute esophageal coin ingestions may experience spontaneous coin passage and therefore, patients with coins located below the thoracic inlet with minor symptoms may be candidates for next-day follow-up. If repeat radiographs reveal a persistent esophageal coin, then the coin should be immediately removed. Furthermore, asymptomatic patients with coins above the thoracic inlet should undergo repeat radiographs in 2-5 h, as spontaneous coin passage may occur. Our protocol may also be more convenient and cost-effective as patients can be observed at home.
-
Pediatric radiology · Dec 2003
Case ReportsHemoptysis: a rare cause can be related to a bronchial varix due to pulmonary venous obstruction.
Bronchial varices, which have rarely been described in the radiology literature, can be the result of pulmonary venous obstruction and may present with hemoptysis. This case is an illustration of this rare condition, which correlates CT findings with bronchoscopic findings. We also describe the findings on phase-contrast MR that demonstrated reversed diastolic flow in the branch pulmonary artery supplying the affected lung.
-
Pediatric radiology · Dec 2003
Case ReportsUtilization of ultrasound for the detection of pneumothorax in the neonatal special-care nursery.
Pneumothorax is a potentially life-threatening condition in the setting of the neonatal special-care nursery (SCN) that may result in rapid deterioration and death. The familiar appearances associated with pneumothorax on AP supine chest radiograph are highly specific, but limited in sensitivity. In this case report, we describe the theory and technique of thoracic ultrasound for detection of pneumothorax in the SCN, providing a viable alternative to the cross-table lateral radiograph without ionising radiation, with highly accurate results, and with minimal patient positioning.
-
Pediatric radiology · Dec 2003
Case ReportsCortical hypoxic-ischemic brain damage in shaken-baby (shaken impact) syndrome: value of diffusion-weighted MRI.
Shaken-baby syndrome (SBS) is a type of child abuse caused by violent shaking of an infant, with or without impact, and characterized by subdural hematomas, retinal hemorrhages, and occult bone fractures. Parenchymal brain lesions in SBS may be missed or underestimated on CT scans, but can be detected at an earlier stage with diffusion-weighted MRI (DW-MRI) as areas of restricted diffusion. We demonstrate the value of DW-MRI in a 2-month-old baby boy with suspected SBS. The pattern of diffusion abnormalities indicates that the neuropathology of parenchymal lesions in SBS is due to hypoxic-ischemic brain injuries, and not to diffuse axonal injury.