Periprosthetic bone remodelling of two types of uncemented femoral implant with proximal hydroxyapatite coating: a 3-year follow-up study addressing the influence of prosthesis design and preoperative bone density on periprosthetic bone loss.
Periprosthetic bone loss is a major cause of concern in patients undergoing total hip arthroplasty (THA). Further studies are required to identify the factors determining the pattern of bone remodelling following THA and obtain improvements in the design and durability of prostheses. In this study, we monitored periprosthetic bone loss around two different types of hydroxyapatite coated femoral implant over a 3-year period to evaluate their design and investigate the relationship with the preoperative bone mineral density (BMD) at the spine, hip and forearm. ⋯ Highly significant relationships were found between periprosthetic bone loss and preoperative BMD measured at the PA spine ( P<0.001), total hip ( P=0.004) and total distal radius ( P<0.001). This study showed differences between two different designs of hydroxyapatite-coated implant that confirmed that prosthesis design influences periprosthetic bone loss. The study also showed that patients' bone density measured at the spine, hip or forearm at the time of operation was a major factor influencing bone loss around the femoral stem.
-
Multicenter Study
Variations in diagnostic performances of dual-energy X-ray absorptiometry in the northwest of The Netherlands.
Between-center variation in bone densitometry may influence the frequency of the diagnosis of osteoporosis. To evaluate this problem, dual-energy X-ray absorptiometry (DXA) machines of the medical centers in the northwest of The Netherlands were evaluated. Four phantoms were used to test the 17 DXA machines of 16 participating centers. ⋯ The clinical impact of the observed differences is difficult to estimate. One may conclude that the differences of the tested DXA devices are partly based on differences in DXA machines, but for the most part on the use of different reference populations. It is recommended to standardize the reference population, although the consequent shift in diagnosis will be confusing for physicians and patients, and adaptation of the reference values on the DXA devices of different brands with different technical qualities and measurement specifications will be difficult.
-
The aim of this study was to measure bone mineral density (BMD) in healthy people and examine the influence of age, anthropometry, and postmenopause on calculated bone mineral apparent density (BMAD). The study included 541 healthy subjects (249 men and 292 women), aged 20 to 79 years. Anthropometric measurements included height, weight, and body mass index (BMI). ⋯ Age and postmenopause were significantly associated with BMD and BMAD in the spine and femur. Furthermore, BMD showed a stronger association with height and weight than BMAD, in both regions. Weaker association of body height and weight with BMAD than with BMD suggests that BMD depends on the bone size and body size and that the different BMDs could be the consequence of the difference in those parameters.