The Annals of pharmacotherapy
-
Background: Lab tests such as activated partial thromboplastin time (aPTT) or anti-factor Xa (anti-Xa) levels are typically used to monitor intravenous unfractionated heparin (IV heparin), with recent evidence suggesting that anti-Xa levels may provide a more accurate measure of anticoagulation. Objective: The Lexington Veterans Affairs Health Care System transitioned from using aPTT to anti-Xa levels in January 2017. This study was conducted to evaluate the efficacy and safety of this change. ⋯ Anti-Xa monitoring was not associated with an increased risk of adverse events. Conclusion and Relevance: Significantly higher IV heparin doses were required to achieve therapeutic anti-Xa levels after transitioning from an aPTT-based protocol in the largely unstudied veteran population. However, the transition from aPTT to anti-Xa monitoring appears safe and efficacious in these patients.