This study examines the value of spin-echo-based fMRI for cognitive studies at the main magnetic field strength of 3 T using a spin-echo EPI (SE-EPI) sequence and a Stroop color-word matching task. SE-EPI has the potential advantage over conventional gradient-echo EPI (GE-EPI) that signal losses caused by dephasing through the slice are not present, and hence although image distortion will be the same as for an equivalent GE-EPI sequence, signal voids will be eliminated. The functional contrast in SE-EPI will be lower than for GE-EPI, as static dephasing effects do not contribute. ⋯ The experiments from visual cortex indicated that at 3 T the BOLD signal change has contributions from the extravascular space and larger blood vessels in roughly equal amounts. In comparison with GE-EPI the absence of static dephasing effects would seem to result in a superior intrinsic spatial resolution. In conclusion the sensitivity of SE-EPI at 3 T is sufficient to make it the method of choice for fMR studies that require a high degree of spatial localization or where the requirement is to detect activation in regions affected by strong susceptibility gradients.