NeuroImage
-
Though emotions have been shown to have sometimes dramatic effects on decision-making, the neural mechanisms mediating these biases are relatively unexplored. Here, we investigated how incidental affect (i.e. emotional states unrelated to the decision at hand) may influence decisions, and how these biases are implemented in the brain. Nineteen adult participants made decisions which involved accepting or rejecting monetary offers from others in an Ultimatum Game while undergoing functional magnetic resonance imaging (fMRI). ⋯ Sad participants also showed a diminished sensitivity in neural regions associated with reward processing (ventral striatum). Importantly, insular activation uniquely mediated the relationship between sadness and decision bias. This study is the first to reveal how subtle mood states can be integrated at the neural level to influence decision-making.
-
The physiological origin of task-evoked systemic artefacts in functional near infrared spectroscopy.
A major methodological challenge of functional near-infrared spectroscopy (fNIRS) is its high sensitivity to haemodynamic fluctuations in the scalp. Superficial fluctuations contribute on the one hand to the physiological noise of fNIRS, impairing the signal-to-noise ratio, and may on the other hand be erroneously attributed to cerebral changes, leading to false positives in fNIRS experiments. Here we explore the localisation, time course and physiological origin of task-evoked superficial signals in fNIRS and present a method to separate them from cortical signals. ⋯ Based on temporal correlation of fNIRS and fMRI signals with peripheral physiological measurements we conclude that the physiological origin of the systemic artefact is a task-evoked sympathetic arterial vasoconstriction followed by a decrease in venous volume. Since changes in sympathetic outflow accompany almost any cognitive and emotional process, we expect scalp vessel artefacts to be present in a wide range of fNIRS settings used in neurocognitive research. Therefore a careful separation of fNIRS signals originating from activated brain and from scalp is a necessary precondition for unbiased fNIRS brain activation maps.
-
In this study, a new approach to high-speed fMRI using multi-slab echo-volumar imaging (EVI) is developed that minimizes geometrical image distortion and spatial blurring, and enables nonaliased sampling of physiological signal fluctuation to increase BOLD sensitivity compared to conventional echo-planar imaging (EPI). Real-time fMRI using whole brain 4-slab EVI with 286 ms temporal resolution (4mm isotropic voxel size) and partial brain 2-slab EVI with 136 ms temporal resolution (4×4×6 mm(3) voxel size) was performed on a clinical 3 Tesla MRI scanner equipped with 12-channel head coil. Four-slab EVI of visual and motor tasks significantly increased mean (visual: 96%, motor: 66%) and maximum t-score (visual: 263%, motor: 124%) and mean (visual: 59%, motor: 131%) and maximum (visual: 29%, motor: 67%) BOLD signal amplitude compared with EPI. ⋯ Two-slab EVI further improved temporal resolution for measuring task-related activation and enabled mapping of five major resting state networks (RSNs) in individual subjects in 5 min scans. The bilateral sensorimotor, the default mode and the occipital RSNs were detectable in time frames as short as 75 s. In conclusion, the high sampling rate of real-time multi-slab EVI significantly improves sensitivity for studying the temporal dynamics of hemodynamic responses and for characterizing functional networks at high field strength in short measurement times.
-
Error detection is essential for monitoring performance and preparing subsequent behavioral adjustments, and is associated with specific neural responses in the anterior cingulate cortex (ACC). To investigate whether different brain mechanisms subserve the processing of commission vs. accuracy errors, we recorded EEG in adult participants while they performed a novel speeded GO-NOGO aiming task ("the Shoot-NoShoot paradigm"). ⋯ Fast hits also elicited a pre-ERN but no ERN, suggesting that this pre-response monitoring component might be related to the detection of error likelihood. Although source analysis revealed similar generators in ACC for these different error-related negativities, the respective timing differed, suggesting that commission errors are detected rapidly based on internal motor representations, whereas the detection of accuracy errors in ACC relies on the additional and swift processing of external visual information.
-
The abilities to empathize and to systemize, two fundamental dimensions of cognitive style, are characterized by apparent individual differences. These abilities are typically measured using an empathizing quotient (EQ) and a systemizing quotient (SQ) questionnaire, respectively. The purpose of this study was to reveal any correlations between EQ and SQ scores and regional gray matter volumes in healthy children by applying voxel-based morphometry to magnetic resonance images. ⋯ The EQ-C scores showed significant positive correlations with the regional gray matter volumes of the left fronto-opercular and superior temporal cortices, including the precentral gyrus, the inferior frontal gyrus, the superior temporal gyrus, and the insula, which are functionally related to empathic processing. Additionally, SQ-C scores showed a significant negative correlation with the regional gray matter volume of the left posterior parietal cortex, which is functionally involved in selective attention processing. Our findings suggest that individual differences in cognitive style pertaining to empathizing or systemizing abilities could be explained by differences in the volume of brain structures that are functionally relevant to empathizing and systemizing.