Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)
-
Comparative Study
Loose versus stranded seeds in permanent prostate brachytherapy: dosimetric comparison of intraoperative plans.
To compare target volume coverage and critical organ dosimetry of intraoperative treatment plans for loose seed (LS) and stranded seed (SS) (125)I permanent implants for low and intermediate risk prostate cancer. ⋯ LS resulted in less dose to the urethra and rectum compared to SS in intraoperative dosimetry. A slightly better target volume coverage with decreased conformity of dose distribution is reported with SS. More studies are necessary to determine how these results will affect postoperative dosimetry, and ultimately, clinical outcome.
-
The accumulated dose to the skin of the patient during fluoroscopically-guided procedures can exceed the thresholds for tissue reactions. In practice, interventionalists have no direct information about the local procedure-related skin doses in their patient, causing suboptimal or delayed treatment. In current study, the accumulated Kerma-Area-Product (KAP) values were registered, as well as the reference air kerma (Ka,r) values, if available, for almost 200 cases undergoing seven different procedures. ⋯ Trigger values in terms of KAP, corresponding to a peak skin dose of 2 Gy, were determined. In general, our results comply reasonably well with the values proposed in the NCRP 168 report, with a KAP value of 425 Gy cm² and a Ka,r value of 3 Gy, corresponding to a peak skin dose of 3 Gy. Only for the TIPSS procedure a considerably lower value of 2 Gy was obtained at the published Ka,r and for the RF ablations we obtained a considerably lower value of 250 Gy cm² in terms of KAP.