Physiological measurement
-
Physiological measurement · Nov 1997
Comparative Study Clinical TrialNon-invasive assessment of cardiac output during exercise in chronic obstructive pulmonary disease: comparison of the CO2-rebreathing method and electrical impedance cardiography.
In exercise testing of patients with chronic obstructive pulmonary disease (COPD), non-invasive assessment of stroke volume (SV) and cardiac output (CO) would be valuable. Electrical impedance cardiography (EIC) has proved to be a valid and reliable instrument in healthy subjects. In this study it is investigated whether this also applies to patients with COPD. ⋯ CO was closely correlated to oxygen uptake using the CO2-rebreathing as well as the EIC method; the slope of the regression line was closer to what has been reported in the literature with EIC. Results were better with the EIC-ht than with the EIC-135 and EIC-150 methods. It is concluded that EIC is a reliable and valid method for measurements of SV and CO in COPD during exercise.