Field-by-field evaluation of intraoperative transoesophageal echocardiography interpretative skills.
A quality assurance system is essential for the credibility and structured growth of anaesthesiology-based transoesophageal echocardiography (TEE) programmes. We have developed software (Q/A Kappa), involving a 400-line source code, capable of directly reporting kappa correlation coefficient values, using external reviewer interpretations as the 'gold standard', and thereby allowing systematic assessment of the validity of intraoperative echocardiographic interpretation. This paper presents assessment of the validity of 240 intraoperative anaesthesiologists' echocardiographic interpretations, and, in addition, the results of field testing of this prototypical software. ⋯ The implications and possible explanations of the results for particular examination fields are discussed. This study also demonstrates successful seamless functioning of this software program from data entry, segmentation into tables and valid statistical analysis. These findings suggest that it is practical to provide sophisticated continuous quality improvement TEE data on a routine basis.