Bench study of the accuracy of a commercial AED arrhythmia analysis algorithm in the presence of electromagnetic interferences.
This paper presents a bench study on a commercial automated external defibrillator (AED). The objective was to evaluate the performance of the defibrillation advisory system and its robustness against electromagnetic interferences (EMI) with central frequencies of 16.7, 50 and 60 Hz. The shock advisory system uses two 50 and 60 Hz band-pass filters, an adaptive filter to identify and suppress 16.7 Hz interference, and a software technique for arrhythmia analysis based on morphology and frequency ECG parameters. ⋯ The specificity for asystole and the sensitivity for VF and rapid VT in the presence of any kind of 16.7, 50 or 60 Hz EMI simulated artifact were shown to reach the equivalence of sensitivity required for non-noisy signals. In conclusion, we proved that the shock advisory system working in a real AED operates accurately according to the AHA recommendations without artifacts and in the presence of EMI. The results may be affected for specificity in the case of a low signal-to-noise ratio or in some extreme frequency setting.
-
Physiological measurement · Jul 2009
Hemodynamic changes in rat leg muscles during tourniquet-induced ischemia-reperfusion injury observed by near-infrared spectroscopy.
In this study, we hypothesized that non-invasive continuous wave near-infrared spectroscopy (CWNIRS) can determine the severity or reversibility of muscle damage due to ischemia/reperfusion (I/R), and the results will be highly correlated with those from physical examination and histological analysis. To test this hypothesis, we performed CWNIRS measurements on two groups of male Sprague-Dawley rats ( approximately 400 g) that underwent 2 h (n = 6) or 3 h (n = 7) of pneumatic tourniquet application (TKA). Tissue oxyhemoglobin [HbO(2)] and deoxyhemoglobin [Hb] concentration changes were monitored during the 2 h or 3 h of 250 mmHg TKA and for an additional 2 h post-TKA. ⋯ We found a significant correlation between the elapsed time from tourniquet release to the first recovery peak of [HbO(2)] and the muscle weight ratio between tourniquet and contralateral limb muscles (R = 0.86). Hemodynamic patterns from non-invasive CWNIRS demonstrated significant differences between 2 h and 3 h I/R. The results demonstrate that CWNIRS may be useful as a non-invasive prognostic tool for conditions involving vascular compromise such as extremity compartment syndrome.